Journal of Infrared and Millimeter Waves, Volume. 41, Issue 3, 597(2022)

Nonlinearity correction of FY-3E HIRAS-II in pre-launch thermal vacuum calibration tests

Tian-Hang YANG1,2,3, Ming-Jian GU1,2、*, Chun-Yuan SHAO1,2, Chun-Qiang WU4, Cheng-Li QI4, and Xiu-Qing HU4
Author Affiliations
  • 1Key Laboratory of Infrared System Detection and Imaging Technology,Chinese Academy of Sciences,Shanghai 200083,China
  • 2Shanghai Institute of Technical Physics,Chinese Academy of Sciences,Shanghai 200083,China
  • 3National Laboratory for Infrared Physics,Shanghai Institute of Technical Physics,Chinese Academy of Science,Shanghai 200083,China
  • 4Key Laboratory of Radiometric Calibration and Validation for Environmental Satellites,National Satellite Meteorology Center,China Meteorological Administration,Beijing 100081,China
  • show less

    The High-spectral Infrared Atmospheric Sounder II (HIRAS-II) is a Fourier transform spectrometer onboard the world’s first civil early-morning-orbiting FengYun 3E (FY-3E) meteorological satellite, the FY-3E/HIRAS-II focus on a number of upgrades such as the sensitivity of the detector, the accuracy of spectral calibration and radiometric calibration, with the designed and manufactured processing based on the first Chinese hyperspectral infrared (IR) sounder FY-3D/HIRAS-I. We conducted a comprehensive pre-launch thermal vacuum (TVAC) calibration tests for HIRAS-II, including the nonlinearity (NL) correction which consists an essential part of radiometric calibration, the NL correction has considerable effects on radiometric accuracy. According to the HIRAS-II nonlinear behavior of the detectors for long-wave (LW) and mid-wave1 (MW1) infrared spectral bands, the NL correction of raw data in the spectral domain is a scaling of the observed spectrum, the NL correction coefficients are derived by the methods of minimizing the spread of the responsivity of reconstructed spectrum in each wavenumber with varying temperature, or minimizing the spread of the bias of brightness temperature among calibration targets with varying temperature. The bias of spectral brightness temperature is assessed by comparing the NL correction and the non-NL correction radiometric calibration data, the results show that, the radiometric accuracy has been significantly improved via NL correction.

    Tools

    Get Citation

    Copy Citation Text

    Tian-Hang YANG, Ming-Jian GU, Chun-Yuan SHAO, Chun-Qiang WU, Cheng-Li QI, Xiu-Qing HU. Nonlinearity correction of FY-3E HIRAS-II in pre-launch thermal vacuum calibration tests[J]. Journal of Infrared and Millimeter Waves, 2022, 41(3): 597

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Research Articles

    Received: Sep. 9, 2021

    Accepted: --

    Published Online: Jul. 8, 2022

    The Author Email: Ming-Jian GU (gumingj@sina.com)