Laser Technology, Volume. 46, Issue 6, 802(2022)

Research on energy calibration device of laser target echo simulator

MENG Qing’an*, FAN Hongying, XUE Liangping, JIANG Zewei, ZHANG Hao, and WANG Xun
Author Affiliations
  • [in Chinese]
  • show less

    In order to solve the problem that the output pulse laser energy of the laser target echo simulator can not be calibrated in the field, the analog integral principle was adopted, the energy calibration device of laser target echo simulator was established through the parameter optimization design of the photoelectric detection module and the circuit structure design of the integral module, and the corresponding experiments were designed to verify the measurement ability of the calibration device. The results show that, the energy calibration device of the laser target echo simulator can accurately measure the laser energy when the pulse width is 10ns~100ns and the energy measurement range is 10fJ~1pJ. The measurement uncertainty is 13.8% when the inclusion factor k is 2. It can fully meet the requirements of the output pulse laser energy measurement and calibration of the laser target echo simulator.

    Tools

    Get Citation

    Copy Citation Text

    MENG Qing’an, FAN Hongying, XUE Liangping, JIANG Zewei, ZHANG Hao, WANG Xun. Research on energy calibration device of laser target echo simulator[J]. Laser Technology, 2022, 46(6): 802

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Oct. 9, 2021

    Accepted: --

    Published Online: Feb. 4, 2023

    The Author Email: MENG Qing’an (mengqing_an@aliyun.com)

    DOI:10-7510/jgjs-issn-1001-3806-2022-06-015