Chinese Optics Letters, Volume. 11, Issue 7, 070604(2013)
Welding-packaged accelerometer based on metal-coated FBG
A fiber Bragg grating-based accelerometer with a fully metalized package is presented. Magnetron sputtering and electroplating techneques are successively adopted to metalize bare SiO2 fiber with a single Bragg grating. Laser welding techneque is adopted to fix the metal-coated fiber on the sensor component to obtain a fully metallized package without adhesives. Vibration test results demonstrate that the accelerometer has a flat frequency response over a 1-kHz bandwidth, with a resonance frequency of 3.6 kHz, wide linear measurement range of up to 8 g, and sensitivity of 1.7 pm/g.
Get Citation
Copy Citation Text
Yongxing Guo, Dongsheng Zhang, Zude Zhou, Li Xiong, Xiwang Deng, "Welding-packaged accelerometer based on metal-coated FBG," Chin. Opt. Lett. 11, 070604 (2013)
Category:
Received: Mar. 13, 2013
Accepted: Apr. 12, 2013
Published Online: Jul. 8, 2013
The Author Email: