Application of Enhanced Photoelectric Coupling and Multi Anode Photoelectric Multiplier Tube Detectors in Biological Aerosol Fluorescence Spectrum Lidar

RAO Zhi-min1,2, LI Yi-cheng1,2, MAO Jian-dong1,2、*, ZHAO Hu1,2, LI Yi-xiu1,2, ZHOU Chun-yan1,2, and GONG Xin1,2
Author Affiliations
  • 1School of Electrical and Information Engineering, North Minzu University, Yinchuan750021, China
  • 2Key Laboratory of Atmospheric Environment Remote Sensing of Ningxia Hui Autonomous Region, Yinchuan750021, China
  • show less

    Biological aerosols can reproduce and cause large-scale diseases in humans, animals, and plants. Therefore, the research on remote warning and real-time detection technology of biological aerosols is significant. Based on ultraviolet laser-induced fluorescence spectrum technology, the application of enhanced photoelectric coupling detector (ICCD) and multi-anode photomultiplier tube detector (MAPMT) in fluorescence spectrum lidar of biological aerosols are elaborated in detail. Furthermore, the signal-to-noise ratio, concentration resolution, and relative deviation of the fluorescence spectrum lidar system composed of ICCD and MAPMT detectors for measuring biological aerosols were studied through numerical simulation. Results showed that when the laser working pulse was 600 during the day, dusk, and night, (1) the systems signal-to-noise ratio was greater than 10. The concentration of biological aerosols is 108 bacteria·L-1, and the detection distances of the fluorescence spectrum lidar system composed of ICCD detectors are 1.1, 3.3 and 3.4 km, respectively. In contrast, the detection distances of MAPMT detectors are 1.3, 8.5 and 11.2 km, respectively. (2) Within a range of 1.0 km, the minimum detection concentrations that the ICCD detector can achieve are 3 081 210, 120 223 and 66 768 bacteria·L-1, while the minimum detection concentrations that MAPMT detectors can achieve are 1 950 637, 71 146 and 37 723 bacteria·L-1. (3) When the detection error is less than 10% and 1%, the relative deviations of the fluorescence spectrum lidar in measuring the concentration of biological aerosols are 33.9%, 37.8% and 40.2% for ICCD detectors, while 37.2%, 42.5% and 46.5% for MAPMT detectors.

    Tools

    Get Citation

    Copy Citation Text

    RAO Zhi-min, LI Yi-cheng, MAO Jian-dong, ZHAO Hu, LI Yi-xiu, ZHOU Chun-yan, GONG Xin. Application of Enhanced Photoelectric Coupling and Multi Anode Photoelectric Multiplier Tube Detectors in Biological Aerosol Fluorescence Spectrum Lidar[J]. Spectroscopy and Spectral Analysis, 2025, 45(4): 1088

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: May. 31, 2024

    Accepted: Apr. 24, 2025

    Published Online: Apr. 24, 2025

    The Author Email: MAO Jian-dong (mao_jiandong@163.com)

    DOI:10.3964/j.issn.1000-0593(2025)04-1088-08

    Topics