Chinese Journal of Lasers, Volume. 46, Issue 6, 0614029(2019)

Terahertz Linear Array Fast Scanning Imaging

Biao Wang1, Xinke Wang1、*, Yue Yu2, and Yan Zhang1
Author Affiliations
  • 1 Department of Physics, Capital Normal University, Beijing 100048, China
  • 2 China Special Equipment Inspection and Research Institute, Beijing 100029, China
  • show less

    A THz linear array scanning imaging system was built using a 0.3 THz radiation source and a linear array detector. The imaging system only needs 1 min to achieve an imaging measurement over a 100 mm×100 mm region at an imaging resolution of 1.5 mm. Using this imaging system, the defects embedded in polyethylene samples and water pipes as well as the scissors and knives concealed in envelopes are quickly and accurately identified. The research results demonstrate that the proposed imaging system can rapidly inspect various objects and is suitable for non-destructive testing and security inspection.

    Tools

    Get Citation

    Copy Citation Text

    Biao Wang, Xinke Wang, Yue Yu, Yan Zhang. Terahertz Linear Array Fast Scanning Imaging[J]. Chinese Journal of Lasers, 2019, 46(6): 0614029

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: terahertz technology

    Received: Jan. 11, 2019

    Accepted: Mar. 4, 2019

    Published Online: Jun. 14, 2019

    The Author Email: Wang Xinke (wxk82721@cnu.edu.cn)

    DOI:10.3788/CJL201946.0614029

    Topics