Experimental investigation on a 10 kW transversal flow discharge CO2laser with tube-plate electrodes

[in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese], and [in Chinese]
Author Affiliations
  • [in Chinese]
  • show less

    A transversal flow CW CO2 laser with pulsed auxiliary discharge was developed. The discharge characteristics was investigated experimentally. The results of gain coefficiant and output power is presented both numerically and experimentally. The maximum output power of 12600 W has been obtained. Sealed-off CW operation for more than 8hrs can be obtained for each gas refilling with of output power 10200 W and power instability of +1.5%.

    Tools

    Get Citation

    Copy Citation Text

    [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese]. Experimental investigation on a 10 kW transversal flow discharge CO2laser with tube-plate electrodes[J]. Chinese Journal of Lasers, 1992, 19(10): 728

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Laser physics

    Received: Dec. 9, 1991

    Accepted: --

    Published Online: Sep. 11, 2007