Opto-Electronic Engineering, Volume. 39, Issue 1, 135(2012)

Beam Hardening Correction of Single-material Objects in CT Imaging

LI Shou-tao*, CHEN Yun-bin, CHEN Hao, WANG Yuan, ZHANG Cheng-xin, and CHEN Si
Author Affiliations
  • [in Chinese]
  • show less

    Currently FBP reconstruction algorithms assume that X-ray which is used to produce projection data is of monoenergy. This presumption is incorrect in reality, which causes the mismatch between the imaging process and the reconstruction algorithms, and leads to the beam hardening phenomenon. We analyze a variety of beam hardening correction algorithms and point out that single-material object linearization is a better method. An improved linearization method is proposed, which solves the problem of how to select the degree of the polynomial and extends the application range of polynomial fitting based on reprojection to cone-beam CT imaging. Finally, experiments are given to prove the practicality and validity of the proposed method.

    Tools

    Get Citation

    Copy Citation Text

    LI Shou-tao, CHEN Yun-bin, CHEN Hao, WANG Yuan, ZHANG Cheng-xin, CHEN Si. Beam Hardening Correction of Single-material Objects in CT Imaging[J]. Opto-Electronic Engineering, 2012, 39(1): 135

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Sep. 7, 2011

    Accepted: --

    Published Online: Feb. 13, 2012

    The Author Email: Shou-tao LI (ssk_2000@163.com)

    DOI:10.3969/j.issn.1003-501x.2012.01.023

    Topics