Chinese Journal of Lasers, Volume. 37, Issue S1, 73(2010)
Experimental Study on Temperature Uniformity of Spray Cooling in Non-Boiling Regime for High-Power Laser
Keeping the heat flux and the temperature of water inlet constant, three full cone nozzles are applied to study the temperature uniformity of spray cooling in non-boiling regime. The influences of nozzle geometry characteristics, spray distance and inlet pressure are studied respectively. The results show that the standard deviation of the surface temperature is affected by nozzle diameter, spray distance and inlet pressure, while the nozzle cone angle has no significant impact on the temperature uniformity.
Get Citation
Copy Citation Text
Si Chunqiang, Liang Nan, Tian Changqing, Xu Hongbo. Experimental Study on Temperature Uniformity of Spray Cooling in Non-Boiling Regime for High-Power Laser[J]. Chinese Journal of Lasers, 2010, 37(S1): 73
Category:
Received: Nov. 30, 2009
Accepted: --
Published Online: Oct. 29, 2010
The Author Email: Chunqiang Si (cqsi@mail.ipc.ac.cn)