Journal of Infrared and Millimeter Waves, Volume. 41, Issue 6, 1072(2022)

Research on imaging model of infrared camera with focal plane detector and its MTF measuring method

Jian KONG1、*, Yu-Tian FU2, and Yue-Jin ZHAO1
Author Affiliations
  • 1Beijing Key Laboratory for Precision Optoelectronic Measurement Instrument and Technology,School of Optics and Photonics,Beijing Institute of Technology,Beijing 100081,China
  • 2Shanghai Institute of Technical Physics,Chinese Academia of Sciences,Shanghai 200083,China
  • show less

    Imaging Model in space domain and frequency domain of an infrared camera with focal plane detector is established. It shows that because of the existence of back ground radiance and non-uniformity the geometrical performance of an infrared camera can be evaluated by MTF only when the camera is well-corrected and the linearity and space invariance condition is satisfied. An MTF measurement method of an infrared camera using focal plane detector is given. This method does not depend on the well correction of the camera and can avoid the deviation from the background radiance.

    Tools

    Get Citation

    Copy Citation Text

    Jian KONG, Yu-Tian FU, Yue-Jin ZHAO. Research on imaging model of infrared camera with focal plane detector and its MTF measuring method[J]. Journal of Infrared and Millimeter Waves, 2022, 41(6): 1072

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Research Articles

    Received: Apr. 18, 2022

    Accepted: --

    Published Online: Feb. 6, 2023

    The Author Email: Jian KONG (13291206@qq.com)

    DOI:10.11972/j.issn.1001-9014.2022.06.017

    Topics