Chinese Journal of Lasers, Volume. 41, Issue 9, 908004(2014)

Synchronization Measurement of Multi-Beams for High Power Laser Facility

Sun Zhihong*, Dong Jun, Peng Zhitao, Lü Jiakun, Xia Yanwen, Lu Zonggui, and Liu Hua
Author Affiliations
  • [in Chinese]
  • show less

    Synchronization measurement of multi-beams for high power laser facility is achieved at the same time. The time correlation and duplicate measurement method, temporal profile diagnostic module of tripled frequency, and the high-speed digital oscillograph and transient photodiode are used. The synchronization adjustment is obtained by arbitrary wave generator and optical delay cell of front end. Results show that the errors of the synchronization measurement are less than 30 ps. The measurement technology and methods are important for synchronization measurement of multi-beam laser facility.

    Tools

    Get Citation

    Copy Citation Text

    Sun Zhihong, Dong Jun, Peng Zhitao, Lü Jiakun, Xia Yanwen, Lu Zonggui, Liu Hua. Synchronization Measurement of Multi-Beams for High Power Laser Facility[J]. Chinese Journal of Lasers, 2014, 41(9): 908004

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: measurement and metrology

    Received: Feb. 27, 2014

    Accepted: --

    Published Online: Jun. 30, 2014

    The Author Email: Zhihong Sun (sunzh01@163.com)

    DOI:10.3788/cjl201441.0908004