Acta Photonica Sinica, Volume. 38, Issue 8, 2063(2009)
Linearly Chirped Long Period Gratings Used for EDFA Gain Flattening
The linearly chirped long period grating with special refractive index for EDFA gain flattening is presented. Runge-Kutta algorithm is used to numerically solve the coupled-mode equations of this type of grating. The grating structure parameters including grating length, period, linear chirp coefficient and the core refractive index profile are optimized by Nelder-Mead arithmetic. A linearly chirped long period grating with appropriate parameters is designed to flatten the gain spectrum of EDFA. The flattened gain spectrum has a bandwidth of 35 nm in C wave band and a fluctuation in ±0.5 dB.