Chinese Journal of Lasers, Volume. 7, Issue 4, 50(1980)
An experimental study and observation by electron microscope on rabbits’liver resection by CW Nd:YAG laser as light scalpel
Pantial liver lobe resection with a CW Nd-YAG laser as light scalpel were carried out in ten adult rabbits,which showed the usefulness of the focused Nd-YAG laser beam in liver surgery. The output power of the laser was 15~20 watts.Measurement of SGPT and blood routine were made preoperatively and postoperatively.The cut edge was bloodless with a 1~3 mm layer of carbonization and coagulation at the surrouding tissure.24 hrs after operation,SGPT increased to more than 130 units,and blood hemoglobin decreased seriously.Both SGPT and blood hemoglobin returned to normal level 7 days after operation.Under microscope,agglutinations of erythrocyte in venules was observed within the necrotic zone 2 mm from the cut edge.The submicroscopic structure of the hepatic cells observed by electron microscope showed different degree of thenmal damage according to their distance from the cut edge.Within distance of 3 mm from the cut edge,the submicroscopic structure was not complete,however,those situated 4~5 mm from the cut edge showed complete submicroscopic structure.Autopsy perfomed 1 to 3 months postoperatively revealed satisfactory healing and liver regeneration without infection.
Get Citation
Copy Citation Text
Liu Bingrong, Shen Fute. An experimental study and observation by electron microscope on rabbits’liver resection by CW Nd:YAG laser as light scalpel[J]. Chinese Journal of Lasers, 1980, 7(4): 50
Category: laser devices and laser physics
Received: Nov. 15, 1979
Accepted: --