Collection Of theses on high power laser and plasma physics, Volume. 13, Issue 1, 93450(2015)

Diagnostics of pulse contrast for p etawatt laser in SGII

Xiaoping Ouyang1、*, Daizhong Liu1, Baoqiang Zhu1, Jian Zhu2, and Jianqiang Zhu1
Author Affiliations
  • 1Joint Laboratory on High Power Laser and Physics, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Science, Shanghai 201800, China
  • 2Shanghai Institute of Laser Plasma, China Academy of Engineering Physics, Shanghai 201800, China
  • show less

    Pulse contrast is an important parameter for ultrafast pulses. It shall be 108 or higher in order to avoid effect from noise before main pulse. Diagnostics with cross-correlation can achieve high temporal resolution such as ~7fs. Cross-correlation has advantage in pulse contrast measurement than autocorrelation because it can distinguish noise before or after main pulse. High dynamic range is also essential in pulse contrast measurement. Cross-correlation signal from a single shot is converted into a signal series through fiber array, which can be analyzed by a set of a PMT and an oscilloscope. Noise from nonlinear crystal and scatter needs decrease to improve dynamic range. And pulse power is also discussed in pulse contrast experiments. Time delay τ is generated by travel stage in measurement for repetition pulses. Then energy instability will generate error in this measurement. In measurement for single shot pulse, time delay τ is generated by slant angle of beams. The scanning procession is completed with thousands parts of beam section within a single shot, and error will generated from no uniformity in near field. Performance test of pulse contrast measurement is introduced in subsequent sections. Temporal resolution is testified by self-calibration. Dynamic range is judged by a parallel flat. At last pulse contrast of petawatt laser is diagnosed by a single shot cross-correlator with high confidence. The ratio is 10-6 at 50ps before main pulse, and 10-4 at 10ps before main pulse.

    Tools

    Get Citation

    Copy Citation Text

    Xiaoping Ouyang, Daizhong Liu, Baoqiang Zhu, Jian Zhu, Jianqiang Zhu. Diagnostics of pulse contrast for p etawatt laser in SGII[J]. Collection Of theses on high power laser and plasma physics, 2015, 13(1): 93450

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: --

    Accepted: --

    Published Online: May. 27, 2017

    The Author Email: Ouyang Xiaoping (oyxp@siom.ac.cn)

    DOI:10.1117/12.2178692

    Topics