Chinese Journal of Lasers, Volume. 14, Issue 7, 406(1987)
Measurement of some CO2 laser dynamic parameters by opto-galvanic spectroscopy
Modulating the CO2 opto-galvanic voltage, signals from CO2-Na-He laser plasma have been analysed. It is shown that the amplitude of the COa opto-galvanic voltage is related to a change of the population of the CO2(0001) level and to the thermal relaxation rates of CO2 levels. Dependence of opto-galvanic voltage on the gain, intensity, dynamic resistance and temperature measured can be expressed by a solution similar to that OGE of CO molecule.
Get Citation
Copy Citation Text
Gui Zenxing, Zhang Shunyi, Shen Guirong, Wang Runwen. Measurement of some CO2 laser dynamic parameters by opto-galvanic spectroscopy[J]. Chinese Journal of Lasers, 1987, 14(7): 406
Category: laser devices and laser physics
Received: --
Accepted: --
Published Online: Aug. 10, 2012
The Author Email:
CSTR:32186.14.