Laser & Optoelectronics Progress, Volume. 49, Issue 11, 111202(2012)

Precision Measurement and Results Analysis of Noise Equivalent Temperature Difference of Cooled HgCdTe Infrared Push-Broom System

Xu Shiwei*, Zhang Yueling, Wang Dapeng, Wei Dong, Liu Wancheng, Zhang Shengchong, and Tang Shuwei
Author Affiliations
  • [in Chinese]
  • show less
    References(13)

    [1] [1] Wang Yifeng, Mao Jingxiang. Computation of scan efficiency of infrared imaging system [J]. Laser & Infrared, 2008, 38(11): 1097~1099

    [2] [2] Song Fenghua. Modern Space Optoelectronics System and Application [M]. Beijing: National Defense Industry Press, 2004. 243~250

    [3] [3] G. C. HOLST. Electro-Opitical Imaging System Performance[M].Winter Park: JCD Publishing, 1995. 362~382

    [4] [4] G. C. Holst. Testing and Evaluation of Infrared Imaging Systems[M]. Winter Park: JCD Publishing; Beijingham: SPIE Optical Engineering Press, 1998

    [5] [5] Feng Kecheng, Liu Jingsheng. Infrared Optics System [M]. Beijing: Enginery Industry Press, 1994. 124~129

    [6] [6] An Chengbin, Wan Ying. Analysis of NETD test for thermal imaging system [J]. Infrared and Laser Engineering, 2010, 39(3): 414~417

    [7] [7] Hu Mingpeng, Ma Dongmei, Li Hongzhuang et al.. The noise model of the staring image system [J]. Laser & Infrared, 2007, 37(9): 863~866

    [8] [8] Hu Tieli, Feng Zhuoxiang, Li Xudong et al.. Modeling and measurement of thermal imager temporal noise[J]. Infrared and Laser Engineering, 2008, 37(2): 519~522

    [9] [9] Jiang Guibin, Lan Tian, Ni Guoqiang. Important parameters and testing methods of performance evaluation of thermal infrared imaging system[J]. Infrared and Laser Engineering, 2008, 37(2): 470~473

    [10] [10] Zhang Cheng, Li Chunming. Research on NETD test of infrared imaging systems [J]. J. Dali University, 2009, 8(4): 37~39

    [11] [11] Hu Mingpeng. Influence and analysis of parameters set on NETD test [J]. Infrared Technology, 2009, 31(1): 27~31

    [13] [13] Wan Ying, Qi Meng. Method of thermal image system auto NETD-measuring [J]. Infrared and Laser Engineering, 2007, 36(10): 1379~1382

    Tools

    Get Citation

    Copy Citation Text

    Xu Shiwei, Zhang Yueling, Wang Dapeng, Wei Dong, Liu Wancheng, Zhang Shengchong, Tang Shuwei. Precision Measurement and Results Analysis of Noise Equivalent Temperature Difference of Cooled HgCdTe Infrared Push-Broom System[J]. Laser & Optoelectronics Progress, 2012, 49(11): 111202

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Instrumentation, Measurement and Metrology

    Received: Jun. 20, 2012

    Accepted: --

    Published Online: Oct. 18, 2012

    The Author Email: Shiwei Xu (xsw19@126.com)

    DOI:10.3788/lop49.111202

    Topics