Acta Optica Sinica, Volume. 37, Issue 10, 1015001(2017)

Wide-Area Monocular Plane Measurement Based on Calibration on a Parallel Plane Using Multiple Targets

Dongsheng Yang, Shusheng Bi, Yueri Cai*, and Chang Yuan
Author Affiliations
  • Robotics Institute, Beihang University, Beijing, 100191, China
  • show less
    Figures & Tables(16)
    Camera model
    Schematic of calibration principle
    Geometrical relationship of plane measurement
    (a) Distribution of measurement precision of different positions in the measuring area; (b) distribution of measurement precision versus xM, when yM=-500 mm; (c) distribution of measurement precision versus yM, when xM=0 mm
    Measurement precision versus camera angles
    Experimental setup
    Target images. (a) First group; (b) second group
    Schematic of precision measurement experiment. (a) Measuring planes; (b) positions of small targets; (c) feature point intervals of a small target
    Measurement error of different positions on 0 mm plane. (a) Absolute error; (b) relative error
    Measurement error of different positions on 100 mm plane. (a) Absolute error; (b) relative error
    Measurement error of different positions on 200 mm plane. (a) Absolute error; (b) relative error
    Relationship between total measurement error and distance of different planes using multi-target method. (a) Absolute error; (b) relative error
    Measurement error distribution of different planes using multi-target method. (a) Absolute error; (b) relative error
    Error of XM and YM axes in different positions on the 50 mm plane. (a) Absolute error; (b) relative error
    • Table 1. Parameters for precision analysis

      View table

      Table 1. Parameters for precision analysis

      Image resolution /(pixel×pixel)fu0v0h /mmθ /(°)δ /pixel
      4032×3024346020161512900251
    • Table 2. Calibration results

      View table

      Table 2. Calibration results

      GroupAk1k2RBTB
      13854.202023.604017.51543.80010.1142-0.21660.99360.1123-0.0135-0.09190.87130.48210.0659-0.47780.8760-547.7-388.21280.9
      23443.101972.103478.51512.20010.1039-0.15590.71320.7009-0.0079-0.62820.64400.43670.3111-0.30650.8996-498.8-409.81155.4
    Tools

    Get Citation

    Copy Citation Text

    Dongsheng Yang, Shusheng Bi, Yueri Cai, Chang Yuan. Wide-Area Monocular Plane Measurement Based on Calibration on a Parallel Plane Using Multiple Targets[J]. Acta Optica Sinica, 2017, 37(10): 1015001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Machine Vision

    Received: Mar. 16, 2017

    Accepted: --

    Published Online: Sep. 7, 2018

    The Author Email: Cai Yueri (caiyueri@buaa.edu.cn)

    DOI:10.3788/AOS201737.1015001

    Topics