Optics and Precision Engineering, Volume. 17, Issue 3, 576(2009)

Localizing and tracking of medical capsule in human by magnetic sensor array

ZHENG Xiao-lin*... LI Jin, HOU Wen-sheng and HE Jin |Show fewer author(s)
Author Affiliations
  • [in Chinese]
  • show less
    References(10)

    [1] [1] LIANG X L,ZHENG X L,HOU W SH, et al.. A design for locating the micro-medical device in human alimentary canal using nuclear imaging technology[J]. China Journal of Medical Imaging Technology, 2006,22(10):1592-1594.(in Chinese)

    [2] [2] JIAN P P,YAN G ZH,WAN W X. Researches on invasive micro-system for whole GI tract physiological parameters monitoring[J]. Robot Technology and Application,2003(4):33-35.(in Chinese)

    [3] [3] FISCHER D, SCHREIBER R, LEVI D, et al.. Capsule endoscope: the localization system[J]. Gastrointestinal Endoscopy Clinics of North America, 2004(14):25-31.

    [6] [6] WANG X N, MENG M Q, HU C. A localization method using 3-axis magnetoresistive sensors for tracking of capsule endoscope [C]. Proc. of the 28th IEEE EMBS, 2006:2522-2525.

    [7] [7] HU C, MENG M Q.-H, Mandal M. Efficient Linear Algorithm for Magnetic Localization and Orientation in Capsule Endoscopy [C]. Proc. of the 2005 IEEE, 27th EMBC,2005:162-167.

    [8] [8] HOU W SH, ZENG X L, PENG CH L,et al.. Study of simplified magnetic location model for micro medical device inside human body[J]. Chinese Journal of Scientific Instrument, 2005,26(9):895-897.(in Chinese)

    [9] [9] FENG C ZH. Electromagnetic Field[M]. Beijing: Higher Education Press, 1983. (in Chinese)

    [10] [10] FAN SH W, ZHANG X ZH. Study of the global optimal method self adaptation simulated annealing genetic algorithm[J]. Opt. Precision Eng.,1999,7(4):16-21.(in Chinese)

    CLP Journals

    [1] GUO Xu-dong, YAN Rong-guo, YAN Guo-zheng. Calibration method for wirelessly localizing capsule endoscopy[J]. Optics and Precision Engineering, 2010, 18(12): 2650

    [2] LONG Liang, ZHONG Shao-long, XU jing, WU Ya-ming. Design and fabrication of micro fiber-optic magnetic sensor[J]. Optics and Precision Engineering, 2013, 21(9): 2294

    Tools

    Get Citation

    Copy Citation Text

    ZHENG Xiao-lin, LI Jin, HOU Wen-sheng, HE Jin. Localizing and tracking of medical capsule in human by magnetic sensor array[J]. Optics and Precision Engineering, 2009, 17(3): 576

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: May. 15, 2008

    Accepted: --

    Published Online: Oct. 28, 2009

    The Author Email: Xiao-lin ZHENG (zxl@cqu.edu.cn)

    DOI:

    CSTR:32186.14.

    Topics