High Power Laser and Particle Beams, Volume. 36, Issue 7, 076001(2024)

Commission method of the primary helium circulator of HTGR under variable resistance condition

Lin Ye... Yijie Yan*, Weiqiang Xu, Feng Zhao, Guangjian Chen, Chao Li and Yingjie Zhu |Show fewer author(s)
Author Affiliations
  • Shandong Shidao Bay Nuclear Power Co., Ltd., China Huaneng Group Co., Ltd., Weihai 264300, China
  • show less
    Figures & Tables(9)
    Primary loop flowchart of HTR-PM
    Relationship between the characteristics of centrifugal fans and the resistance of pipe network
    Schematic diagram of working medium flow in centrifugal impeller
    Schematic diagram of centrifugal impeller outlet velocity triangle
    Distribution of the cold test operation points of the primary helium circulator on its performance curve
    Distribution of thermal test operation points of the primary helium circulator on its performance curve
    • Table 1. Main parameters of primary helium circulator

      View table
      View in Article

      Table 1. Main parameters of primary helium circulator

      working fluidpressure/MPaflow rate/(kg/s)pressure rise/kParated speed/(r/min)rated electrical power/kW
      helium79620040004500
    • Table 2. Conversion of test pressure of primary helium circulator

      View table
      View in Article

      Table 2. Conversion of test pressure of primary helium circulator

      testworking fluidtemperature/℃pressure/MPapower*/kWdensity/(kg/m3)
      *: $ {n}_{\max} $ is equal to 4000 r/min
      monomeric testair19.30.101019.11.19
      cold testair25.00.454500.05.27
      hot testhelium250.05.734500.05.27
    • Table 3. Operation of primary helium circulator under different working conditions

      View table
      View in Article

      Table 3. Operation of primary helium circulator under different working conditions

      work conditionspeed/(r/min)current/Avoltage/Vpower/kWpressure rise/kPaflow rate/(kg/s)pressure/MPainlet temperature/℃
      ①: primary helium circulator operation at 200 MW②: the hot function test of primary helium circulator③: rated parameters and some design limits for primary helium circulator
      3600523.756144218122.2127.36.9239.9
      400051661474648145.2116.05.31235.9
      380058060004500200967.0243
    Tools

    Get Citation

    Copy Citation Text

    Lin Ye, Yijie Yan, Weiqiang Xu, Feng Zhao, Guangjian Chen, Chao Li, Yingjie Zhu. Commission method of the primary helium circulator of HTGR under variable resistance condition[J]. High Power Laser and Particle Beams, 2024, 36(7): 076001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Dec. 20, 2023

    Accepted: Apr. 2, 2024

    Published Online: Jun. 21, 2024

    The Author Email: Yan Yijie (yyjwolf9527@163.com)

    DOI:10.11884/HPLPB202436.230444

    Topics