High Power Laser and Particle Beams, Volume. 36, Issue 7, 076001(2024)

Commission method of the primary helium circulator of HTGR under variable resistance condition

Lin Ye... Yijie Yan*, Weiqiang Xu, Feng Zhao, Guangjian Chen, Chao Li and Yingjie Zhu |Show fewer author(s)
Author Affiliations
  • Shandong Shidao Bay Nuclear Power Co., Ltd., China Huaneng Group Co., Ltd., Weihai 264300, China
  • show less

    During the commissioning of the primary helium circulator of the high-temperature gas-cooled reactor (HTGR), it could not complete the performance test of the full speed range, because the resistance of the primary loop was lower than the design condition. Based on the theoretical characteristics of the primary helium circulator and similar principles, a method for calculating the commission parameters of the primary helium circulator under different resistance conditions was developed. Combined with the monomeric test operating points of the primary helium circulator, the method was used to accurately calculated the operating point parameters of the cold and hot performance tests of the primary helium circulator, and guide the completion of the full speed and full power performance tests of the primary helium circulator in HTGR. By comparing and analyzing the commission and factory test results of the primary helium circulator, the feasibility of this calculation method is verified, and correction factors for the conversion of working conditions between air medium and helium medium is provided. Through comparing and analyzing the commission and operation data of the primary helium circulator, it can be seen that the commission conditions provided in this article have sufficient enveloping ability, which can cover all operating conditions of the primary helium circulator during the operation of HTGR. This proves that the variable resistance condition commission method of the primary helium circulator meets the performance verification requirements of HTGR, and it can be used to guide the primary helium circulator commission of subsequent HTGRs.

    Keywords
    Tools

    Get Citation

    Copy Citation Text

    Lin Ye, Yijie Yan, Weiqiang Xu, Feng Zhao, Guangjian Chen, Chao Li, Yingjie Zhu. Commission method of the primary helium circulator of HTGR under variable resistance condition[J]. High Power Laser and Particle Beams, 2024, 36(7): 076001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Dec. 20, 2023

    Accepted: Apr. 2, 2024

    Published Online: Jun. 21, 2024

    The Author Email: Yan Yijie (yyjwolf9527@163.com)

    DOI:10.11884/HPLPB202436.230444

    Topics