Infrared and Laser Engineering, Volume. 45, Issue 7, 705005(2016)

Laser source used in accurate measurement of mid-infrared absolute spectral responsivity of detectors

Zhao Kun1、*, Shi Xueshun1,2, Liu Changming1, Liu Yulong1, Chen Haidong1, Liu Hongbo1, Chen Kunfeng1, and Li Ligong1,2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    References(14)

    [1] [1] Fan Jinxiang, Li Liang, Li Wenjun. Development of direct infrared countermeasure system and technology[J]. Infrared and Laser Engineering, 2015, 44(3): 789-794. (in Chinese)

    [3] [3] Liu Jianguo, Liu Wenqing, Zhang Yujun, et al. Detection of formaldehyde using mid-infrared difference-frequency-based tunable absorption spectrometer at room temperature[J]. Infrared and Laser Engineering, 2006, 35(S): 211-215.(in Chinese)

    [4] [4] Hoyt C, Foukal P. Cryogenic radiometers and their application to the metrology[J]. Metrologia, 1991, 28(3): 163-167.

    [5] [5] Xueshun S, Kunfeng C, Hongyuan L, et al. Experimental study on absolute spectral responsivity value transfer with cryogenic radiometer[C]//SPIE, 2009, 7511: 75111A-1-6.

    [6] [6] Shi Xueshun, Chen Kunfeng, Wang Hengfei, et al. Experimental studies on Si trap detector absolute spectral responsivity calibration[J]. Optics & Optoelectronic Technology, 2009, 7(5): 63-65. (in Chinese)

    [7] [7] Shi Xueshun, Liu Changming, Liu Yulong, et al. Absolute spectral responsivity of silicon trap detector based on absolute cryogenic radiometer[C]//the International Conference on Photonics and Optical Engineering, Proc.of SPIE, 2014, 9449: 94490U-1-94490U-6.

    [8] [8] Liu Changming, Shi Xueshun, Liu Yulong, et al. Determination of absolute spectral response and quantum efficiency of Si trap detector in band of 325-980 nm[J]. Journal of Optoeletronics Laser, 2015, 26(4): 667-670. (in Chinese)

    [9] [9] Liu Yulong, Liu Changming, Shi Xueshun, et al. Development of the transfer standard of near infrared absolute spectral response[J]. Journal of Astronautic Metrology and Measurement, 2015, 35(3): 48-54. (in Chinese)

    Tools

    Get Citation

    Copy Citation Text

    Zhao Kun, Shi Xueshun, Liu Changming, Liu Yulong, Chen Haidong, Liu Hongbo, Chen Kunfeng, Li Ligong. Laser source used in accurate measurement of mid-infrared absolute spectral responsivity of detectors[J]. Infrared and Laser Engineering, 2016, 45(7): 705005

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: 激光技术及应用

    Received: Nov. 5, 2015

    Accepted: Dec. 3, 2015

    Published Online: Aug. 18, 2016

    The Author Email: Kun Zhao (kunzhao41@163.com)

    DOI:10.3788/irla201645.0705005

    Topics