Infrared and Laser Engineering, Volume. 53, Issue 11, 20240352(2024)

Fourier transform infrared spectrometer based on graphene photodetection

Naxi LIU1,2,3,4,5, Shenao ZHAO1,2,3,4,5, Renkang SONG1,2,3,4,5, Lei ZHOU1,2,3,4,5, Baoning WANG1,2,3,4,5, Di HUANG1,2,3,4,5, Bin MA1,2,3,4,5, and Tao JIANG1,2,3,4,5
Author Affiliations
  • 1Institute of Precision Optical Engineering, Shanghai 200092, China
  • 2MOE Key Laboratory of Advanced Micro-Structured Materials, Shanghai 200092, China
  • 3Shanghai Frontiers Science Center of Digital Optics, Shanghai 200092, China
  • 4Shanghai Professional Technical Service Platform for Full-Spectrum and High-Performance Optical Thin Film Devices and Applications, Shanghai 200092, China
  • 5School of Physics Science and Engineering, Tongji University, Shanghai 200092, China
  • show less
    Figures & Tables(4)
    Schematic diagram of the FTIR spectrometer based on graphene photodetection and characterization of the photocurrent signal from the graphene photodetector. (a) Schematic illustration of the FTIR optical path structure; (b) Optical microscope image of the graphene device; (c) Photocurrent microscopy images of the graphene device at different wavelengths; (d) Dependence of the photocurrent response intensity of graphene on the excitation light power at wavelengths of 2400 nm and 5000 nm
    Comparison of the spectral test results of the FTIR spectrometer at different scanning distances and scanning speeds. (a) Scanning speed; (b) Scanning distance ( For clarity, an intensity offset of 1 was added between adjacent scanning speeds and scanning distances)
    Spectral accuracy testing of the FTIR spectrometer based on graphene photodetection under excitation at different wavelengths. (a) Time-domain interferogram of 2200 nm; (b) Time-domain interferogram of 2300 nm; (c) Time-domain interferogram of 2500 nm; (d) Frequency-domain spectrum of 2200 nm; (e) Frequency-domain spectrum of 2300 nm; (f) Frequency-domain spectrum of 2500 nm
    PDMS FTIR characterization results. (a) FTIR spectrum; (b) Absorption spectrum
    Tools

    Get Citation

    Copy Citation Text

    Naxi LIU, Shenao ZHAO, Renkang SONG, Lei ZHOU, Baoning WANG, Di HUANG, Bin MA, Tao JIANG. Fourier transform infrared spectrometer based on graphene photodetection[J]. Infrared and Laser Engineering, 2024, 53(11): 20240352

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: 红外技术及应用

    Received: Aug. 6, 2024

    Accepted: --

    Published Online: Dec. 13, 2024

    The Author Email:

    DOI:10.3788/IRLA20240352

    Topics