Acta Optica Sinica, Volume. 41, Issue 7, 0722002(2021)

Design of Optical System for Broadband and Integrated AOTF Imaging Spectrometer

Lingying Chang1, Qiang Zhang1、*, and Yuehong Qiu2
Author Affiliations
  • 1School of Electronic Engineering, Xi′an University of Posts & Telecommunications, Xi′an, Shaanxi 710121, China;
  • 2Xi′an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi′an, Shaanxi 710119, China
  • show less
    Figures & Tables(13)
    Framework of AOTF imaging spectrometer
    Schematic AOTF
    Layout diagram of whole optical system
    Structure of optical system
    MTF curves of each wave band. (a) 0.4--1.0 μm; (b) 1.0--3.0 μm; (c) 3.0--5.0 μm
    Distortion curve of optical system
    Ray aberration curves of optical system
    • Table 1. Parameters of CCD

      View table

      Table 1. Parameters of CCD

      Type of CCDWavelength /μmResolution ratio /(pixel×pixel)Pixel size /μmManufacturer
      C9100-23BC10633-34LCT6500.4--1.01.0--3.03.0--5.0512×512640×512640×480162028HamamatsuHamamatsuLMT
    • Table 2. Optical parameters of each optical system

      View table

      Table 2. Optical parameters of each optical system

      Optical systemf' /mmF2ω /(°)Special requirement
      Front optical system12555.3/
      Collimating system12555.3The aperture stop is in front
      AOTF///The whole system aperture stop is located on it
      Imaging system12555.3The aperture stop is in front
    • Table 3. Decentration and tilt of each mirror in collimation system and imaging system

      View table

      Table 3. Decentration and tilt of each mirror in collimation system and imaging system

      ParameterM1M2M3
      Decentration /mm-2.259.71-42.62
      Tilt /(°)-8.8514.94-9.46
      Conic constant-0.0057-0.59710.2905
      4th order coefficient3.2099×10-81.1255×10-74.5249×10-9
      6th order coefficient6.8373×10-13-7.0802×10-12-1.3881×10-12
    • Table 4. Free-form surface parameters of 2th and 3th mirrors of front optical system

      View table

      Table 4. Free-form surface parameters of 2th and 3th mirrors of front optical system

      ParameterM5M6
      x2-0.0002106972160320470.000255701901033404
      y2-0.00171804160559217-0.000236872764458664
      x2y9.04570554409036×10-56.20840490996327×10-5
      y32.00886732732122×10-52.4067793728652×10-5
      x48.14765363997121×10-71.11814320160958×10-6
      x2y21.07561516752013×10-61.93207601895823×10-6
      y4-5.15133651906762×10-76.9508661703245×10-8
      x2y31.63554420207729×10-77.35226113716151×10-8
      x4y1.06110204783277×10-76.55137454872012×10-8
      y54.59026670330349×10-84.82190236092222×10-9
      x62.94401246962391×10-9-1.98161446537076×10-10
      x4y26.81970754121763×10-91.71051475340913×10-9
      x2y43.89696710828571×10-91.0572403532361×10-9
      y66.27978015435262×10-103.26946542626363×10-12
    • Table 5. Decentration and tilt of each mirror of front optical system

      View table

      Table 5. Decentration and tilt of each mirror of front optical system

      ParameterM4M5M6
      Decentration /mm-50.0013.5131.97
      Tilt /(°)-10.989.7615.39
    • Table 6. MTF values of whole optical system

      View table

      Table 6. MTF values of whole optical system

      Spatialfrequency /(lp·mm-1)Spectralband /μmWavelength /μmMTF
      500.4--1.00.40.50.70.91.00.7870.7710.7070.6510.621
      201.0--3.01.01.52.02.53.00.8450.7780.7110.6430.577
      123.0--5.03.03.54.04.55.00.7420.7010.6590.6190.579
    Tools

    Get Citation

    Copy Citation Text

    Lingying Chang, Qiang Zhang, Yuehong Qiu. Design of Optical System for Broadband and Integrated AOTF Imaging Spectrometer[J]. Acta Optica Sinica, 2021, 41(7): 0722002

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Optical Design and Fabrication

    Received: Oct. 9, 2020

    Accepted: Nov. 23, 2020

    Published Online: Apr. 11, 2021

    The Author Email: Zhang Qiang (johnson_zhang1994@126.com)

    DOI:10.3788/AOS202141.0722002

    Topics