Acta Optica Sinica, Volume. 32, Issue 1, 101004(2012)
Spectral Irradiance Calibration Research of the Solar Backscattered Ultraviolet Spectroradiometer in Air/Vacuum Conditions
[4] [4] Huang Yu, Wang Shurong, Zhang Zhenduo et al.. Spectral irradiance calibration of remote sensing ultraviolet spectral radiometer in space[J]. J. Optoelectronics·Laser, 2008, 19(4): 466~469
[5] [5] Huang Yu, Wang Shurong, Zhang Zhenduo et al.. Spectral irradiance calibration of space remote sensing spectral radiometer in range of UV and VUV[J]. Acta Photonica Sinica, 2007, 36(B6): 187~191
[6] [6] J. H. Walker, R. D. Saunders, J. K. Jackson et al.. NBS Measurement Services: Spectral Irradiance Calibrations [M]. Washington: U.S Government Printing Office, 1987. 1~101
[7] [7] Huang Yu. Study on Radiometric Calibration of Ozone Vertical Detector [D]. Changchun: Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, 2007.14~36
[8] [8] M. T. DeLand, Liangkang Huang, C. A. McKay. NOAA-17 SBUV/2(FM#6) Activation and Evaluation Phase(A&E) Report[R]. Science Systems and Applications, Inc.: Document #SSAI-2015-180-MD-2002-02, 1~102
[9] [9] Zhang Zhenduo. High-Accuracy Irradiance Responsivity Calibration of Solar Backscatter Ultraviolet Spectrometer[D]. Changchun: Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, 2010.17~34
[10] [10] W. K. Fowler, K. W. Kelly, D. F. Heath. Implications of measured differences in the spectroradiometric sensitivity of SBUV/2 instruments in air and vacuum on long term measurements of stratospheric ozone and solar irradiance variations from space[C]. SPIE, 1996, 2815: 69~83
[11] [11] Liu Ying, Li Futian. MgF2-overcoated aluminium films for ultraviolet and vacuum ultraviolet[J]. Optics and Precision Engineering, 2001, 9(4): 165~168
[12] [12] Zhigang Li, Futian Li. Simple UV-VUV beamsplitter coatings for Fourier transform spectrometers [J]. Meas. Sci. Technol., 2000, 11(1): N11~N14
[13] [13] L. K. Huang, R. P. Cebula, E. Hilsenrath. New procedure for interpolating NIST FEL lamp irradiances[J]. Metrologia, 1998, 35(4): 381~386
[14] [14] Yang Xiaohu, Wang Shurong, Huang Yu et al.. Wavelength dependence of the spectral irradiance of standard lamp and bi-reflection distribution function of diffuser based on standard detectors[J]. Acta Optica Sinica, 2011, 31(6): 0612008
Get Citation
Copy Citation Text
Yang Xiaohu, Wang Shurong, Huang Yu. Spectral Irradiance Calibration Research of the Solar Backscattered Ultraviolet Spectroradiometer in Air/Vacuum Conditions[J]. Acta Optica Sinica, 2012, 32(1): 101004
Category: Atmospheric Optics and Oceanic Optics
Received: Jul. 14, 2011
Accepted: --
Published Online: Jan. 4, 2012
The Author Email: Xiaohu Yang (yangxiaohu861106@163.com)