Optics and Precision Engineering, Volume. 21, Issue 8, 1974(2013)
Improvement of model performance for near-infrared non-invasive biochemical analysis by pathlength correction space method
[1] [1] HEISE H M, MARBCH R.Multivariate determination of blood substrates in human plasma by FT-NIR spectroscopy[J].The International Society for Optical Engineering, 1991,1575: 507-508.
[2] [2] AMEROV A K, CHEN J, AMOLD M A.Scattering and absorption effects in the determination of glucose in whole blood by near-infrared spectroscopy [J].Analytical Chemistry, 2005,77: 4587-4594.
[4] [4] ALEXEEVA N V,ARNOLD M A.Impact of tissue heterogeneity on noninvasive near infrared glucose measurements in interstitial fluid of rat skin [J].Journal of Diabetes Science and Technology, 2010,4: 1041-1054.
[7] [7] CHEN X D. Possibility of noninvasive clinical biochemical examination by near infrared spectroscopy [J]. Opt. Precision Eng., 2008, 16(5): 759-763. (in Chinese)
[8] [8] CHEN X D, GAO J, DING H Q. Infrared spectroscopy for non-invasive blood glucose monitoring[J].Chinese Optics, 2012(4): 317-326.(in Chinese)
[9] [9] YAMAKOSHI K, YAMAKOSHI Y.Pulse glucometry: a new approach for noninvasive blood glucose measurement using instantaneous differential near-infrared spectrophotometry [J].Journal of Biomedical Optics, 2006,11(5): 054028.
[11] [11] YANG Y, CHEN W L, SHI ZH ZH, et al.. Reference point of floating-reference method for blood glucose sensing [J]. Chinese Optics Letters,2010,8(4): 421-424.
[14] [14] LORBER A.Error propagation and figures of merit for quantification by solving matrix equations [J].Analytical Chemistry,1986, 58: 1167-1172.
[15] [15] LORBER A.Net analyte signal calculation in multivariate calibration [J].Analytical Chemistry,1997,69: 1620-1626.
[16] [16] OLESBERG J T, LIU L, ZEE V V, et al..In vivo near-infrared spectroscopy of rat skin tissue with varying blood glucose levels [J].Analytical Chemistry, 2006,78(1): 215-223
[17] [17] OLESBERG J T, AMOLD M A, HU S B.Temperature-insensitive near-infrared method for determination of protein concentration during protein crystal growth[J].Analytical Chemistry,2000,72(20): 4985-4990.
[18] [18] RILEY M R, ARNOLD M A, MURHAMMER D W.Effect of sample complexity on quantification of analytes aqueous samples by near-infrared spectroscopy [J].Applied Spectroscopy, 2000,54(2): 255-261.
[19] [19] LIU R, CHEN W L, GU X Y, et al.. Extraction of net analyte signal in the noninvasive blood glucose sensing [J].Nanotechnology and Precision Engineering, 2008,6(3): 207-211.(in Chinese)
[21] [21] YANG H M, GAO H ZH, WANG D M, et al.. Study on determination of cholesterol and triglyceride in human serum utilizing Near-infrared water windows[C]. Proceedings of the 2nd Chinese Conference on Near Infrared Spectroscopy, 2008: 311-314. (in Chinese)
[22] [22] AMEROV A K, CHEN J, SMALL G W.Molar absorptivities of glucose and other biological molecules in aqueous solutions over the first overtone and combination regions of the near-infrared Spectrum[J].Applied Spectroscopy, 2004,58(10): 1195-1204.
Get Citation
Copy Citation Text
GAO Hong-zhi, LU Qi-peng, DING Hai-quan, CHEN Si-wei. Improvement of model performance for near-infrared non-invasive biochemical analysis by pathlength correction space method[J]. Optics and Precision Engineering, 2013, 21(8): 1974
Category:
Received: Jan. 22, 2013
Accepted: --
Published Online: Sep. 6, 2013
The Author Email: Hong-zhi GAO (ghonzi@163.com)