Semiconductor Optoelectronics, Volume. 41, Issue 4, 472(2020)

Design and Robust Analysis of Allfibertype Sideviewing OCT Probe

MA Jing1... WANG Yingqi2, HU Yuntao3 and HUO Li1 |Show fewer author(s)
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3[in Chinese]
  • show less
    References(11)

    [1] [1] Huang D, Swanson E A, Lin C P, et al. Optical coherence tomography[J]. Science, 1991, 254(5035): 11781181.

    [2] [2] Luo S, Liu H, Zhao H, et al. Gastric and colon cancer imaging with swept source optical coherence tomography[C]// 2017 Conf. on Lasers and ElectroOptics Pacific Rim (CLEOPR). IEEE, 2017: 13.

    [3] [3] Yaqoob Z, Wu J, McDowell E J, et al. Methods and application areas of endoscopic optical coherence tomography[J]. J. of Biomedical Optics, 2006, 11(6): 063001.

    [4] [4] Wojtkowski M, Kowalczyk A, Leitgeb R, et al. Full range complex spectral optical coherence tomography technique in eye imaging[J]. Opt. Lett., 2002, 27(16): 14151417.

    [5] [5] Xi J, Huo L, Wu Y, et al. Highresolution OCT balloon imaging catheter with astigmatism correction[J]. Opt. Lett., 2009, 34(13): 19431945.

    [6] [6] Lorenser D, Yang X, Kirk R W, et al. Ultrathin sideviewing needle probe for optical coherence tomography[J]. Opt. Lett., 2011, 36(19): 38943896.

    [7] [7] Li H, Standish B A, Mariampillai A, et al. Feasibility of interstitial Doppler optical coherence tomography for in vivo detection of microvascular changes during photodynamic therapy[J]. Lasers in Surgery and Medicine: The Official J. of the American Society for Laser Medicine and Surgery, 2006, 38(8): 754761.

    [8] [8] Wang C, Fang C, Tang Z, et al. Analytical method for designing gradientindex fiber probes[J]. Optical Engin., 2011, 50(9): 094202.

    [9] [9] Fu H L, Leng Y, Cobb M J, et al. Flexible miniature compound lens design for highresolution optical coherence tomography balloon imaging catheter[J]. J. of Biomedical Opt., 2008, 13(6): 060502.

    [10] [10] Jung W, Benalcazar W A, Ahmad A, et al. Numerical analysis of gradient index lensbased optical coherence tomography imaging probes[J]. J. of Biomedical Opt., 2010, 15(6): 066027.

    [11] [11] Griffith D J, Ruppeiner G. Introduction to electrodynamics[J]. American J. of Phys., 1981, 49(12): 11881189.

    Tools

    Get Citation

    Copy Citation Text

    MA Jing, WANG Yingqi, HU Yuntao, HUO Li. Design and Robust Analysis of Allfibertype Sideviewing OCT Probe[J]. Semiconductor Optoelectronics, 2020, 41(4): 472

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Mar. 27, 2020

    Accepted: --

    Published Online: Aug. 18, 2020

    The Author Email:

    DOI:10.16818/j.issn1001-5868.2020.04.003

    Topics