Optics and Precision Engineering, Volume. 30, Issue 4, 478(2022)

Two-step calibration for vision measurement system with large field of view and high depth

Hao HU1... Bin WEI2,*, Jin LIANG3, Huigang WANG1 and Yongqing ZHANG1 |Show fewer author(s)
Author Affiliations
  • 1Qingdao Research Institute, School of Marine Science and Technology, Northwestern Polytechnical University, Xi'an70072, China
  • 2School of Mechanical Engineering, Hebei University of Science and Technology, Shijiazhuang050091, China
  • 3School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an710049, China
  • show less
    Figures & Tables(19)
    Camera imaging model
    Flowchart of two-step calibration
    Principle of pyramid method
    Flow chart of 3D reconstruction process of the photogrammetry
    Coding mark point
    Experiment environment
    Schematic diagram of internal parameter calibration
    Image acquisition and coding point recognition for internal parameter calibration
    Image acquisition and coding point recognition for internal parameter calibration
    Error distribution of reprojection
    Invar alloy standard ruler
    Images of the ruler in different positions
    Experiment site of the rotor tower
    Total pitch angle of the rotor
    Result of three-dimensional deformation of the rotor
    Result of total pitch angle of the rotor
    • Table 1. Result of internal parameter calibration

      View table
      View in Article

      Table 1. Result of internal parameter calibration

      内参数相机1相机2
      f/pixel2 387.474 42 394.803 1
      Δx/pixel13.282 036.931 2
      Δy/pixel0.826 5-10.424 4
      K1-1.97e-008-2.007e-008
      K23.464e-0155.401e-015
      K31.01e-021-4.958e-022
      B1-2.693e-008-3.6e-008
      B2-2.177e-0084.703e-008
      E10.000 168 96.427e-005
      E2-2.403e-005-6.581e-005
    • Table 2. Result of external parameter calibration

      View table
      View in Article

      Table 2. Result of external parameter calibration

      外参数相机1相机2

      R

      T/mm

      1 0 0

      0 1 0

      0 0 1

      0 0 0

      0.878 6 0.088 51 0.469 3

      -0.061 76 0.995 5 -0.072 13

      -0.473 6 0.034 39 0.880 1

      3 851 -399.6 -1 096

    • Table 3. Result of length measurement

      View table
      View in Article

      Table 3. Result of length measurement

      测量

      位置

      测量值

      /mm

      标称值

      /mm

      绝对误差/mm相对误差%
      16 100.1526 100.0570.0950.002
      26 100.2946 100.0570.2370.004
      36 100.1646 100.0570.1070.002
      46 100.1636 100.0570.1060.002
      56 100.1476 100.0570.0900.001
      66 099.9376 100.0570.1200.002
      76 099.6926 100.0570.3650.006
      86 100.4766 100.0570.4190.007
      96 099.8476 100.0570.2100.003
      106 099.7326 100.0570.3250.005
      116 100.2266 100.0570.1690.003
      126 099.6726 100.0570.3850.006
      136 099.6556 100.0570.4020.007
      146 100.2476 100.0570.1900.003
      156 100.4096 100.0570.3520.006
    Tools

    Get Citation

    Copy Citation Text

    Hao HU, Bin WEI, Jin LIANG, Huigang WANG, Yongqing ZHANG. Two-step calibration for vision measurement system with large field of view and high depth[J]. Optics and Precision Engineering, 2022, 30(4): 478

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites