High Power Laser and Particle Beams, Volume. 32, Issue 4, 043001(2020)

Electron beam introduction of Ka-band coaxial multi-beam relativistic klystron amplifier

Zhiwei Dang1...2, Shifeng Li1,2, Zhanliang Wang1,*, Hua Huang2, Tengfang Wang2, Zhenbang Liu2 and Yubin Gong1 |Show fewer author(s)
Author Affiliations
  • 1School of Electronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu 610054, China
  • 2National Key Laboratory of Science and Technology on High Power Microwave Technology, Institute of Applied Electronics, China Academy of Engineering Physics, Mianyang 621900, China
  • show less
    Figures & Tables(13)
    Schematic of multi-beam diode
    Initial multi-beam electron beam
    Electric field distribution on cathode
    Optimized multi-beam electron beams
    Total beam current and drift tube current
    Photo of the diode for experiment and its sectional schematic
    Cathodes of the diode
    Experimental waveforms
    Multiple electron beam spots on the drift tube port and on the drift tube end
    • Table 1. Effects of multi-beam cathode length on injection efficiency

      View table
      View in Article

      Table 1. Effects of multi-beam cathode length on injection efficiency

      L/mm total beam current/kAdrift tube current/kAefficiency/%
      85.563.970.1
      105.654.274.3
      155.764.476.4
    • Table 2. Effects of magnetic field intensity on injection efficiency

      View table
      View in Article

      Table 2. Effects of magnetic field intensity on injection efficiency

      B0/T total beam current/kAdrift tube current/kAefficiency/%
      0.84.363.375.7
      0.94.333.683.1
      1.04.353.785.1
    • Table 3. Effects of voltage on injection efficiency

      View table
      View in Article

      Table 3. Effects of voltage on injection efficiency

      V/kV total beam current/kAdrift tube current/kAefficiency/%
      4003.122.786.5
      5004.354.186.3
      6005.644.885.1
    • Table 4. Effects of distance between anode and cathode on injection efficiency

      View table
      View in Article

      Table 4. Effects of distance between anode and cathode on injection efficiency

      D/mm total beam current/kAdrift tube current/kAefficiency/%
      255.284.789.0
      304.754.186.3
      354.353.785.0
    Tools

    Get Citation

    Copy Citation Text

    Zhiwei Dang, Shifeng Li, Zhanliang Wang, Hua Huang, Tengfang Wang, Zhenbang Liu, Yubin Gong. Electron beam introduction of Ka-band coaxial multi-beam relativistic klystron amplifier[J]. High Power Laser and Particle Beams, 2020, 32(4): 043001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: May. 30, 2019

    Accepted: --

    Published Online: Mar. 30, 2020

    The Author Email: Wang Zhanliang (wangzl@uestc.edu.cn)

    DOI:10.11884/HPLPB202032.190192

    Topics