Optics and Precision Engineering, Volume. 29, Issue 11, 2581(2021)

Abnormal diagnosis of fiber Bragg grating strain gauges in health monitoring system

Xiao SUN1、*, Qing-mei WANG2, Zhen-wei LI1, and Jing-jing CHU1
Author Affiliations
  • 1College of Automation and Electronic Engineering, Qingdao University of Science and Technology, Qingdao26606, China
  • 2National Astronomical Observatories, Chinese Academy of Science, Beijing10001, China
  • show less
    Figures & Tables(9)
    Original samples of measuring point example
    Samples after compression and filtering of measuring point example
    Frequency characteristics example of compressed signal
    Flow chart of loop iteration
    Simulation experiment results
    Result of sensor abnormal diagnosis
    • Table 1. Failure types and characteristic change of sensors

      View table
      View in Article

      Table 1. Failure types and characteristic change of sensors

      Types of sensors faultsEigen values
      Sensor stuckNo change in output
      Constant gainIncrease in output amplitude
      Complete failureRandom output signal
      Open circuitNo output
      High frequency disturbanceSignal main frequency cycle offset
    • Table 2. Eigen values and abnormal indexes of simulated sensors

      View table
      View in Article

      Table 2. Eigen values and abnormal indexes of simulated sensors

      Sensor numberSample lengthStandard deviation/nmEnergy value/nm2Main cycle/hAbnormal index
      Average609 2660.0895.5622.791.384 9
      Center630 7680.0864.0719.47-
      10157 7220.0720.2643.896.903 3
      11630 8870.28848.1719.488.738 4
      12630 8870.00.006.414 9
      13630 8870.1010.5987.644.928 1
    • Table 3. Eigen values and abnormal indexes of fault sensors

      View table
      View in Article

      Table 3. Eigen values and abnormal indexes of fault sensors

      Sensor numberSample lengthStandard deviation/nmEnergy value/nm2Main cycle/hAbnormal index
      Average554 1200.0894.0832.982.317 5
      Center590 6670.0854.0918.42-
      38130.0440.000.0010.645
      163618 7210.1757.3928.666.955 3
      265103 1860.0730.287.227.706 1
      305682 3800.29935.549.4927.168
    Tools

    Get Citation

    Copy Citation Text

    Xiao SUN, Qing-mei WANG, Zhen-wei LI, Jing-jing CHU. Abnormal diagnosis of fiber Bragg grating strain gauges in health monitoring system[J]. Optics and Precision Engineering, 2021, 29(11): 2581

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Modern Applied Optics

    Received: Mar. 15, 2021

    Accepted: --

    Published Online: Dec. 10, 2021

    The Author Email: SUN Xiao (sx@qust.edu.cn)

    DOI:10.37188/OPE.20212911.2581

    Topics