Optical Instruments, Volume. 45, Issue 4, 40(2023)

Design of a solar blind ultraviolet optical system for corona detection

Liang SHEN... Shihong ZHU and Xiuling LIANG* |Show fewer author(s)
Author Affiliations
  • Fujian Provincial Key Laboratory of Photonics Technology, Key Laboratory of Optoelectronic Science and Technology for Medicine (Ministry of Education), College of Photonic and Electronic Engineering, Fujian Normal University, Fuzhou 350007, China
  • show less
    Figures & Tables(14)
    2D diagram of initial structure
    2D diagram of final structure
    Spot diagram
    MTF curves
    Diffraction encircled energy
    Curves of distortion
    MTF curves at −20 ℃ and 60 ℃
    Diagram of compensation structure
    Actual compensation and ideal offset
    MTF curves after compensation at −20 ℃ and 60 ℃
    • Table 1. Key design parameters of optical system

      View table
      View in Article

      Table 1. Key design parameters of optical system

      参数
      波长/nm240~280
      焦距/mm50
      相对孔径1/2.5
      靶面尺寸/mmΦ18
      MTF(@20 lp/mm) 畸变 ≥0.3 ≤3
    • Table 2. Ideal image plane offset at −20 -60 ℃

      View table
      View in Article

      Table 2. Ideal image plane offset at −20 -60 ℃

      温度/℃−20−100102030405060
      偏移量/mm−0.1313−0.0992−0.0665−0.033300.03460.06920.10430.1299
    • Table 3. Tolerance allocation of the system

      View table
      View in Article

      Table 3. Tolerance allocation of the system

      表面 序号 半径公差 /光圈 厚度 公差/mm 表面偏心 公差/mm 元件偏心 公差/mm 元件倾斜 公差/° 表面不规 则度 折射率 公差 阿贝数 公差/%
      1±4±0.03±0.02±0.02±0.05±0.5±0.001±1
      2±4±0.03±0.02±0.5
      3±4±0.03±0.02±0.02±0.05±0.5±0.001±1
      4±4±0.03±0.02±0.5
      5±4±0.03±0.02±0.02±0.05±0.5±0.001±1
      6±4±0.03±0.02±0.5
      7±4±0.03±0.02±0.02±0.05±0.5±0.001±1
      8±4±0.03±0.02±0.5
      9±4±0.03±0.02±0.02±0.05±0.5±0.001±1
      10±4±0.03±0.02±0.5
    • Table 4. Results of Monte Carlo tolerance analysis

      View table
      View in Article

      Table 4. Results of Monte Carlo tolerance analysis

      蒙特卡洛百分比/%MTF(@ 20 lp/mm)RMS光斑半径/mm
      ≥900.43910.0205
      ≥800.51180.0198
      ≥500.58240.0167
      ≥200.62550.0122
      ≥100.64940.0106
    Tools

    Get Citation

    Copy Citation Text

    Liang SHEN, Shihong ZHU, Xiuling LIANG. Design of a solar blind ultraviolet optical system for corona detection[J]. Optical Instruments, 2023, 45(4): 40

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: OPTICAL SYSTEM

    Received: Dec. 11, 2022

    Accepted: --

    Published Online: Sep. 26, 2023

    The Author Email: LIANG Xiuling (xlliang@fjnu.edu.cn)

    DOI:10.3969/j.issn.1005-5630.2023.004.006