Acta Photonica Sinica, Volume. 45, Issue 6, 604001(2016)

Measurement and Correction of Linearity of Photon Counters

HU You-bo1...2,*, LI Jian-jun2, XIA Mao-peng2, GAO Dong-yang2 and ZHENG Xiao-bing2 |Show fewer author(s)
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    References(16)

    [1] [1] SU Bi-da,WANG Jing-feng,MA Xue-song, et al. Measurement of the photon emission characteristic of silicon avalanche photodiode[J]. Acta Photonica Sinica, 2015, 44(1):0125003.

    [3] [3] KARAMI M A, SANI A A, GHORMISHI M H. Tunneling in submicron CMOS single-photon avalanche diodes[J]. Chinese Optics Letters, 2014, 12(1): 012501.

    [4] [4] YIN Wen-ye,SHI Feng, HE Wei-ji. Distance estimation method based on photon counting lidar[J]. Acta Photonica Sinica, 2015, 44(5): 0501002.

    [7] [7] COMELLI D, ANDREA C D, VALENTINI G, et al. Analyzing integrated circuits at work with a picosecond time-gated imager[J]. Optics Express, 2005, 13(25): 10075-10084.

    [8] [8] ZHANG Xiang-xue , ZHANG Li.The method to calibarte a single photon counter[J]. Optical Technique,2007,33(24),561-563.

    [10] [10] SWYTD A,LAROCK J G. Inverse-fourth apparatus for photometric calibrations[J].Review of Scientific Instruments, 1978,49(8):1083-l089.

    [11] [11] YIN Jian-ping.The nonlinear errors and sensitivity of PMT photo counting system[J]. Chinese Journal of Scientific Instrument. 1985,6(3) :227-235.

    [12] [12] GAO Yan-lei, LU Xiao-gang, BAI Jin-hai, et al. Avalanche luminescence crosstalk between avalanche photodiodes[J]. Acta Optica Sinica, 2015, 35(7): 0727004.

    [13] [13] BUMHAM D C, WEIGBERG D L.Observation of simultaneity in parametric production of optical photon pairs[J].Physical Review Letter,1970, 25(2):84-87.

    [14] [14] BRIDA G, GENOVESEA M, NOVERO C.On the measurement of photon flux in parametric down-conversion[J].European Physical Journal D,2000,8: 273-275.

    [15] [15] WANG Hai-ke,LU Yun-peng. Characteristics and application of photoelectric magnification tube[J].Instrumentation Analysis Monitoring, 2005,1: 1-4.

    [16] [16] WEI Fu-li,WANG Pei-wei,YUAN Yuan,et al. The study of linear current extention of PMT[J].Nuclear Electronics & Detection Technology.2011,31(9):986-990.

    CLP Journals

    [1] GAO Dong-yang, LIU Chang-ming, HU You-bo, SHI Xue-shun, XIA Mao-peng, LI Jian-jun, ZHENG Xiao-bing, WANG Heng-fei. Intercomparison of Correlated Photon Method Based on Continuous Wave and Pulsed Laser Pumping[J]. Acta Photonica Sinica, 2019, 48(6): 612002

    [2] SHI Xue-shun, LIU Chang-ming, ZHAO Kun, CHEN Hai-dong. Measurement System for Quantum Efficiency of the Single Photon Detector Based on Correlated Photons[J]. Acta Photonica Sinica, 2017, 46(3): 304001

    [3] GUO Yuan-yuan, GAO Dong-yang, HU You-bo, LI Jian-jun, ZHENG Xiao-bing, YAN Jing. Experimental Research on Single-photon Detector Calibration and Comparison for the Collinear and Nonlinear Phase Matching Modes[J]. Acta Photonica Sinica, 2017, 46(2): 223001

    Tools

    Get Citation

    Copy Citation Text

    HU You-bo, LI Jian-jun, XIA Mao-peng, GAO Dong-yang, ZHENG Xiao-bing. Measurement and Correction of Linearity of Photon Counters[J]. Acta Photonica Sinica, 2016, 45(6): 604001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Dec. 4, 2015

    Accepted: --

    Published Online: Jul. 26, 2016

    The Author Email: HU You-bo (hgdhyb2010@163.com)

    DOI:10.3788/gzxb20164506.0604001

    Topics