Acta Photonica Sinica, Volume. 40, Issue 11, 1686(2011)
Calibration of Phaseshifted Sensitivity of Optical Fiber Hydrophone in the Frequency Range 20 Hz to 10 kHz
[1] [1] BUCARO J A, DARDY H D, CAROME E. Fiberoptic hydrophone[J]. J Acoust Soc Am, 1977, 62(5): 13021304.
[2] [2] GAO Xuemin. Evolution of fiber optic hydrophones and hydrophone arrays[J]. Optical Fiber & Electric Cable, 1996, (1): 4853.
[3] [3] NASH P. Review of interferometric optical fiber hydrophone technique[J]. IEEE ProcRadar, Sonar Navig, 1996, 143(3): 204209.
[4] [4] CAO Jianian, BAO Jianxin, LI Xuyou, et al. Optical fiber hydrophone[J]. The Technology of Optical Communications, 1997, 21(2): 9094.
[5] [5] CLAY K K, ANTHONY D. Overview of high performance fiberoptic sensing[J]. J Phys D: Appl Phys, 2004, 37(18): 197216.
[6] [6] CUI Sanlie, ZHOU Fuhong, XU Yande. Investigation on the acoustomotive pressure sensitivity of a single mode fiber hydrophone[J]. Acta Photonica Sinica, 1995, 24(1): 7277.
[7] [7] ZHENG Chengdong, ZHENG Li, HE Junhua, et al. Study on characters and experiment of FBG hydrophone[J]. Acta Photonica Sinica, 2006, 35(12): 19341940.
[8] [8] LI Zhizhong, CHENG Yusheng, HU Yongming, et al. Research on a passive fiber grating hydrophone based on polymer sidehole package structure[J]. Acta Acoustica, 2008, 33(5): 469474.
[9] [9] YIN Kai, ZHANG Min, DING Tianhuai, et al. Analysis of the pressure phase sensitivity response of the airbacked mandrel fiberoptic hydrophone[J]. Acta Photonica Sinica, 2009, 38(7): 16411646.
[10] [10] HUANG Shengye, JIN Xiaofeng, ZHANG Jun, et al. An optical fiber hydrophone using equivalent phase shift fiber Bragg grating for underwater acoustic measurement[J]. Photonic Sensors, 2011, 1(3): 289294.
[11] [11] TAKAHASHI S, KIKUCHI T, OHKURA K. Measurement of acoustic sensitivity of fibers used for optical fiber hydrophones[J]. Acoustica, 1986, 60: 7577.
[12] [12] XUE Yaoquan, ZHANG Han. Investigation on the method of calibrating sensitivity of interference type optical fiber hydrophone[J]. Journal of Aeronautic Metrology and Measurement. 1999, 19(4):36.
[13] [13] CHEN Yi. Simulation experiment and precision analysis of evaluation of phasedshifted amplitude of interometric optical fiber hydrophone using Bessel function method[J]. Acoustics and Electronic Engineering, 2004, 76(4): 69.
[14] [14] JIANG Yi, LIU Li. Fiber optical FabryPerot vibration sensor[J]. Acta Photonica Sinica, 2003, 32(9): 10591062.
[15] [15] ZHAO Hongxia, YU Youlong, LIU Shengchun. A fiber Bragg grating sensor demodulation scheme based on a parasitic interference configuration[J]. Acta Photonica Sinica, 2004, 33(6): 669671.
[16] [16] WANG Liwei, LIU Yang, ZHANG Min, et al. Analysis and improvement of the phase generator carrier method in fiber interferometer sensors[J]. Acta Photonica Sinica, 2009, 38(4):766769.
[17] [17] PENG Baojin, LIAO Mao, LIAO Yanbiao, et al. Study on measuring sensitivity of fiberoptic hydrophone[J]. Acta Photonica Sinica, 2005, 34(11): 16331638.
[19] [19] JING Zhenguo, YIN Kai, ZHANG Min, et al. Polarization induced fading eliminating technique for interferometric optical fiber sensor[J]. Acta Photonica Sinica, 2009, 38(8): 20242027.
[20] [20] BIPM, IEC, IFCC, ISO, IUPAC, IUPAP, OIML. Guide to the expression of uncertainty in measurement[M]. Geneva, Switzerland: International Organization for Standardization, 1995.
Get Citation
Copy Citation Text
CHEN Yi, ZHANG Jun, ZHANG Min, WANG Liwei. Calibration of Phaseshifted Sensitivity of Optical Fiber Hydrophone in the Frequency Range 20 Hz to 10 kHz[J]. Acta Photonica Sinica, 2011, 40(11): 1686
Received: May. 26, 2011
Accepted: --
Published Online: Dec. 12, 2011
The Author Email: Yi CHEN (y.chen@163.com)