Chinese Optics Letters, Volume. 7, Issue 1, 0160(2009)

Raman spectroscopic identification of normal and malignant hepatocytes

Jianyu Guo, Bing Du, Min Qian, Weiying Cai, Zugeng Wang, and Zhenrong Sun
Author Affiliations
  • State Key Laboratory of Precision Spectroscopy (East China Normal University), Department of Physics, and Department of Biology, East China Normal University, Shanghai 200062
  • show less
    References(32)

    [1] [1] L. L. Wong, Am. J. Surg. 183, 309 (2002).

    [2] [2] Y. S. Kim, S. Y. Sohn, and C. N. Yoon, Biomed. Pharmacother. 57, 482 (2003).

    [3] [3] Y. H. Ko, P. L. Pedersen, and J. F. Geschwind, Cancer Lett. 173, 83 (2001).

    [4] [4] J.-S. Huang, C.-C. Chao, T.-L. Su, S.-H. Yeh, D.-S. Chen, C.-T. Chen, P.-J. Chen, and Y.-S. Jou, Biochem. Biophys. Res. Commun. 315, 950 (2004).

    [5] [5] R. Malini, K. Venkatakrishna, J. Kurien, K. M. Pai, L. Rao, V. B. Kartha, and C. M. Krishna, Biopolymers 81, 179 (2006).

    [6] [6] P. Crow, A. Molckovsky, N. Stone, J. Uff, B. Wilson, and L.-M. Wongkeesong, Urology 65, 1126 (2005).

    [7] [7] N. Stone, C. Kendall, N. Shepherd, P. Crow, and H. Barr, J. Raman Spectrosc. 33, 564 (2002).

    [8] [8] A. S. Haka, K. E. Shafer-Peltier, M. Fitzmaurice, J. Crowe, R. R. Dasari, and M. S. Feld, PNAS 102, 12371 (2005).

    [10] [10] Z. Huang, A. McWilliams, H. Lui, D. I. McLean, S. Lam, and H. Zeng, Int. J. Cancer 107, 1047 (2003).

    [11] [11] R. Manoharan, Y. Wang, and M. S. Feld, Spectrochim. Acta Part A 52, 215 (1996).

    [12] [12] J. Choi, J. Choo, H. Chung, D.-G. Gweon, J. Park, H. J. Kim, S. Park, and C.-H. Oh, Biopolymers 77, 264 (2005).

    [13] [13] S. Fendel and B. Schrader, Fresenius’ J. Anal. Chem. 360, 609 (2002).

    [14] [14] S. R. Hawi, W. B. Campbell, A. Kajdacsy-Balla, R. Murphy, F. Adar, and K. Nithipatikom, Cancer Lett. 110, 35 (1996).

    [15] [15] A. Gaigneaux, J.-M. Ruysschaert, and E. Goormaghtigh, Eur. J. Biochem. 269, 1968 (2002).

    [16] [16] I. Notingher, S. Verrier, S. Haque, J. M. Polak, and L. L. Hench, Biopolymers 72, 230 (2003).

    [17] [17] A. T. Tu, Raman Spectroscopy in Biology: Principles and Applications (Wiley, New York, 1982) p.72.

    [18] [18] P. R. Carey, Biochemical Applications of Raman and Resonance Raman Spectroscopies (Academic, New York, 1982) p.71.

    [19] [19] C. Krafft, T. Knetschke, A. Siegner, R. H. W. Funk, and R. Salzer, Vibrat. Spectrosc. 32, 75 (2003).

    [20] [20] I. Notingher, J. Selvakumaran, and L. L. Hench, Biosensors Bioelectron. 20, 780 (2004).

    [22] [22] B. R. Wood, B. Tait, and D. McNaughton, Biochim Biophys. Acta 1539, 58 (2001).

    [23] [23] H. P. Buschman, G. Deinum, J. T. Motz, M. Fitzmaurice, J. R. Kramer, A. van der Laarse, A. V. Bruschke, and M. S. Feld, Cardiovasc. Pathol. 10, 69 (2001).

    [24] [24] K. C. Schuster, E. Urlaub, and J. R. Gapes, J. Microbiol. Methods 42, 29 (2000).

    [25] [25] N. Fujioka, Y. Morimoto, T. Arai, and M. Kikuchi, Cancer Detection and Prevention 28, 32 (2004).

    [26] [26] C. Eliasson, J. Engelbrektsson, A. Lorén, J. Abrahamsson, K. Abrahamsson, and M. Josefson, Chemometrics and Intelligent Laboratory 81, 13 (2006).

    [27] [27] C. Xie, J. Mace, M. A. Dinno, Y. Q. Li, W. Tang, R. J. Newton, and P. J. Gemperline, Anal. Chem. 77, 4390 (2005).

    [28] [28] P. Crow, J. S. Uff, J. A. Farmer, M. P. Wright, and N. Stone, BJU International 93, 1232 (2004).

    [29] [29] T. Hasegawa, J. Nishijo, and J. Umemura, Chem. Phys. Lett. 317, 642 (2000).

    [30] [30] B. J. Marquardt and J. P. Wold, Lebensm. Wiss. u. Technol. 37, 1 (2004).

    [31] [31] C. M. Krishna, G. D. Sockalingum, G. Kegelaer, S. Rubin, V. B. Kartha, and M. Manfait, Vibrat. Spectrosc. 38, 95 (2005).

    [32] [32] Z. Seregély, T. Deák, and G. D. Bisztray, Chemometrics and Intelligent Laboratory 72, 195 (2004).

    CLP Journals

    [1] Liu Shupeng, Zhu Hongfei, Chen Na, Chen Zhenyi, Hu Ling. Surface Enhanced Raman Scattering Spectrum Analysis of Nude Mouse Serum with Au Nanoparticles Active Substrate[J]. Chinese Journal of Lasers, 2012, 39(5): 504004

    [2] Wang Guiwen, Peng Lixin, Chen Ping, Yao Huilu, Huang Shushi, Tao Zhanhua, Li Yongqing. Single-Cell Raman Spectroscopy of Erythrocytes from Hemoglobin Bart′s Hydrops[J]. Chinese Journal of Lasers, 2009, 36(10): 2651

    Cited By
    Tools

    Get Citation

    Copy Citation Text

    Jianyu Guo, Bing Du, Min Qian, Weiying Cai, Zugeng Wang, Zhenrong Sun. Raman spectroscopic identification of normal and malignant hepatocytes[J]. Chinese Optics Letters, 2009, 7(1): 0160

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Jun. 17, 2008

    Accepted: --

    Published Online: Mar. 4, 2009

    The Author Email:

    DOI:10.3788/COL20090701.0060

    Topics