Acta Optica Sinica, Volume. 36, Issue 8, 834001(2016)

Projection Decomposition Algorithm for X-Ray Dual-Energy Computed Tomography Based on Isotransmission Line Fitting

Li Lei1、*, Wang Linyuan1, Cai Ailong1, Han Yu1, Yan Bin1, and Bao Shanglian2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    References(14)

    [1] [1] Johnson T R. Dual-energy CT: General principles[J]. American Journal of Roentgenology, 2012, 199(5): S3-S8.

    [2] [2] Zhao Yunsong, Zhang Huitao, Zhao Xing, et al. Iterative reconstruction model and reconstruction method for dual energy computed tomography[J]. Acta Electronica Sinica, 2014, 42(4): 666-671.

    [3] [3] Li Baolei, Zhang Yaojun. Projection decomposition algorithm of X-ray dual-energy computed tomography based on projection matching[J]. Acta Optica Sinica, 2011, 31(3): 0311002.

    [4] [4] Fessler J A, Elbakri I A, Sukovic P, et al. Maximum-likelihood dual-energy tomographic image reconstruction[C]. SPIE, 2002, 4684: 38-49.

    [5] [5] Sukovic P, Clinthorne N H. Penalized weighted least-squares image reconstruction for dual energy X-ray transmission tomography[J]. IEEE Transactions on Medical Imaging, 2000, 19(11): 1075-1081.

    [6] [6] Dong X, Niu T Y, Zhu L. Combined iterative reconstruction and image-domain decomposition for dual energy CT using total-variation regularization[J]. Medical Physics, 2014, 41(5): 051909.

    [7] [7] Niu T Y, Dong X, Petrongolo M, et al. Iterative image-domain decomposition for dual-energy CT[J]. Medical Physics, 2014, 41(4): 041901.

    [8] [8] Alvarez R E, Macovski A. Energy selective reconstruction in X-ray computed tomography[J]. Physics in Medicine and Biology, 1976, 21(5): 733-744.

    [9] [9] Kalender W A, Perman W H, Vetter J R, et al. Evaluation of a prototype dual-energy computed tomographic apparatus. I. Phantom studies[J]. Medical Physics, 1986, 13(3): 334-339.

    [10] [10] Ying Z, Naidu R, Crawford C R. Dual energy computed tomography for explosive detection[J]. Journal of X-Ray Science and Technology, 2006, 14(4): 235-256.

    [11] [11] Tang Z W, Hu G S. Dual energy CT imaging in cone-beam micro-CT for improved attenuation coefficient measurement[J]. Tsinghua Science and Technology, 2011, 16(4): 352-357.

    [12] [12] Liu Y Y, Cheng J P, Zhang L, et al. A low-cost dual energy CT system with sparse data[J]. Tsinghua Science and Technology, 2014, 19(2): 184-194.

    [13] [13] Sidky E Y, Yu L F, Pan X C, et al. A robust method of X-ray source spectrum estimation from transmission measurements: Demonstrated on computer simulated, scatter-free transmission data[J]. Journal of Applied Physics, 2005, 97: 124701.

    CLP Journals

    [1] Mo Jingqing, Xu Pin, Sun Mingshan. Projective Decomposition Algorithms for X-Ray Dual-Energy Bone Densitometer Based on Photon Counting Detectors[J]. Laser & Optoelectronics Progress, 2017, 54(10): 101102

    [2] KONG Xia, PAN Jin-xiao, ZHAO Xiao-jie, CHEN Ping, LI Yi-hong. Multi-Component Decomposition of 3D Block-Matched Dual-Energy CT With Interlayer Constraint[J]. Spectroscopy and Spectral Analysis, 2023, 43(3): 774

    Tools

    Get Citation

    Copy Citation Text

    Li Lei, Wang Linyuan, Cai Ailong, Han Yu, Yan Bin, Bao Shanglian. Projection Decomposition Algorithm for X-Ray Dual-Energy Computed Tomography Based on Isotransmission Line Fitting[J]. Acta Optica Sinica, 2016, 36(8): 834001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: X-Ray Optics

    Received: Feb. 29, 2016

    Accepted: --

    Published Online: Aug. 18, 2016

    The Author Email: Lei Li (leehotline@aliyun.com)

    DOI:10.3788/aos201636.0834001

    Topics