Optics and Precision Engineering, Volume. 26, Issue 10, 2355(2018)

Development of swept source based on dual filtering

CHEN Ming-hui*... JIA Wen-yu, HE Jin-tao, QIN Xian-fu and ZHENG Gang |Show fewer author(s)
Author Affiliations
  • [in Chinese]
  • show less
    References(20)

    [1] [1] DE BOER J F, LEITGE R, WOJTKOWSKI M. Twenty-five years of optical coherence tomography: the paradigm shift in sensitivity and speed provided by Fourier domain OCT [J]. Biomed Opt Express, 2017, 8(7): 3248-3280.

    [2] [2] HILLMANN D, BONIN T, L HRS C, et al.. Common approach for compensation of axial motion artifacts in swept-source OCT and dispersion in Fourier-domain OCT [J]. Opt Express, 2012, 20(6): 6761-6776.

    [3] [3] DHALLA A-H, NANKIVIL D, IZATT J A. Complex conjugate resolved heterodyne swept source optical coherence tomography using coherence revival [J]. Biomed Opt Express, 2012, 3(3): 633-649.

    [4] [4] WOJTKOWSKI M. High-speed optical coherence tomography: basics and applications [J]. Appl Opt, 2010, 49(16): D30-D61.

    [5] [5] GORA M, KARNOWSKI K, SZKULMOWSKI M, et al.. Ultra high-speed swept source OCT imaging of the anterior segment of human eye at 200 kHz with adjustable imaging range [J]. Opt Express, 2009, 17(17): 14880-14894.

    [6] [6] CASTONGUAY A, LEFEBVRE J, POULIOT P, et al. Serial optical coherence scanning reveals an association between cardiac function and the heart architecture in the aging rodent heart [J]. Biomed Opt Express, 2017, 8(11): 5027-5038.

    [7] [7] TUCKER-SCHWARTZ J M, BEAVERS K R, SIT W W, et al.. In vivo imaging of nanoparticle delivery and tumor microvasculature with multimodal optical coherence tomography [J]. Biomed Opt Express, 2014, 5(6): 1731-1743.

    [8] [8] AHN Y-C, KIM S W, HWANG S S, et al.. Optical imaging of subacute airway remodeling and adipose stem cell engraftment after airway injury [J]. Biomed Opt Express, 2014, 5(1): 312-321.

    [10] [10] CHOMA M A, SARUNIC M V, YANG C, et al.. Sensitivity advantage of swept source and Fourier domain optical coherence tomography [J]. Opt Express, 2003, 11(18): 2183-2189.

    [11] [11] WATANABE Y, SAJIMA F, ITAGAKI T, et al.. High-speed linear detection time domain optical coherence tomography with reflective grating-generated spatial reference delay [J]. Appl Opt, 2009, 48(18): 3401-3406.

    [12] [12] LI K, CHASE C, QIAO P, et al.. Widely tunable 1060-nm VCSEL with high-contrast grating mirror [J]. Opt Express, 2017, 25(10): 11844-11854.

    [13] [13] ZARA J M, YAZDANFAR S, RAO K D, et al.. Electrostatic micromachine scanning mirror for optical coherence tomography [J]. Opt Lett, 2003, 28(8): 628-630.

    [14] [14] ZHANG J, JING J, WANG P, et al.. Polarization-maintaining buffered Fourier domain mode-locked swept source for optical coherence tomography [J]. Opt Lett, 2011, 36(24): 4788-4790.

    [15] [15] AVANAKI M R N, BRADU A, PODOLEANU A. Optimization of excitation of fiber Fabry–Perot tunable filters used in swept lasers using a phase-correction method [J]. Appl Opt, 2017, 56(12): 3378-3382.

    [16] [16] LU C D, KRAUS M F, POTSAID B, et al.. Handheld ultrahigh speed swept source optical coherence tomography instrument using a MEMS scanning mirror [J]. Biomed Opt Express, 2014, 5(1): 293-311.

    [17] [17] JOHN D D, BURGNER C B, POTSAID B, et al.. Wideband electrically pumped 1050-nm MEMS-tunable VCSEL for ophthalmic imaging [J]. J. Lightwave Technol., 2015, 33(16): 3461-3468.

    [18] [18] CAO J, WANG P, ZHANG Y, et al.. Methods to improve the performance of the swept source at 1.0 μm based on a polygon scanner [J]. Photon. Res., 2017, 5(3): 245-250.

    [19] [19] HARIRI S, MOAYED A A, DRACOPOULOS A, et al.. Limiting factors to the OCT axial resolution for in-vivo imaging of human and rodent retina in the 1060nm wavelength range [J]. Opt Express, 2009, 17(26): 24304-24316.

    [20] [20] PAN C. Research and Application of Swept Source Optical Coherence Tomography and Its Functional Imaging [D]. Hangzhou: Zhejiang University, 2016. (in Chinese)

    CLP Journals

    [1] Wang Yusu, Guo Jianzeng, Ren Xiaoming, Liu Xiankui, Zhao Haitao, Niu Zhifeng, Wang Zhenhua. Real-time detection method of laser beam defocusing amount based on three spot sizes[J]. Infrared and Laser Engineering, 2019, 48(8): 805001

    [2] CHEN Ming-hui, WANG Fan, ZHANG Chen-xi, LI Fu-gang, ZHENG Gang. Sparse reconstruction of frequency domain OCT image based on compressed sensing[J]. Optics and Precision Engineering, 2020, 28(1): 189

    Tools

    Get Citation

    Copy Citation Text

    CHEN Ming-hui, JIA Wen-yu, HE Jin-tao, QIN Xian-fu, ZHENG Gang. Development of swept source based on dual filtering[J]. Optics and Precision Engineering, 2018, 26(10): 2355

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Jun. 12, 2018

    Accepted: --

    Published Online: Dec. 26, 2018

    The Author Email: Ming-hui CHEN (cmhui.43@163.com)

    DOI:10.3788/ope.20182610.2355

    Topics