    References(21)

    [2] Zhang J Y, Ren J J, Chen S H et al. Application of wavelet denoising in terahertz nondestructive detection[J]. Chinese Journal of Lasers, 47, 0114001(2020).

    [3] Lu X X, Sun H H, Chang T Y et al. Terahertz detection of porosity and porous microstructure in pharmaceutical tablets: a review[J]. International Journal of Pharmaceutics, 591, 120006(2020).

    [4] Hakobyan D, Hamdi M, Redon O et al. Non-destructive evaluation of ceramic porosity using terahertz time-domain spectroscopy[J]. Journal of the European Ceramic Society, 42, 525-533(2022).

    [5] Ye D D, Wang W Z, Zhou H T et al. In-situ evaluation of porosity in thermal barrier coatings based on the broadening of terahertz time-domain pulses: simulation and experimental investigations[J]. Optics Express, 27, 28150-28165(2019).

    [6] Bawuah P, Mendia A P, Silfsten P et al. Detection of porosity of pharmaceutical compacts by terahertz radiation transmission and light reflection measurement techniques[J]. International Journal of Pharmaceutics, 465, 70-76(2014).

    [7] Lai H B, He M X, Tian T et al. Porosity of tablets based on terahertz spectroscopy[J]. Acta Optica Sinica, 38, 0630001(2018).

    [8] Markl D, Bawuah P, Ridgway C et al. Fast and non-destructive pore structure analysis using terahertz time-domain spectroscopy[J]. International Journal of Pharmaceutics, 537, 102-110(2018).

    [9] Bawuah P, Chakraborty M, Ervasti T et al. A structure parameter for porous pharmaceutical tablets obtained with the aid of Wiener bounds for effective permittivity and terahertz time-delay measurement[J]. International Journal of Pharmaceutics, 506, 87-92(2016).

    [10] Zhang T Y, Zhang Z H, Arnold M. Dielectric analysis of polymeric materials and mixtures using terahertz time domain spectroscopy[J]. Spectroscopy and Spectral Analysis, 39, 1689-1694(2019).

    [11] Parrott E P, Zeitler J A, Gladden L F. Accurate determination of optical coefficients from chemical samples using terahertz time-domain spectroscopy and effective medium theory[J]. Optics Letters, 34, 3722-3724(2009).

    [12] Anuschek M, Bawuah P, Zeitler J A. Terahertz time-domain spectroscopy for powder compact porosity and pore shape measurements: an error analysis of the anisotropic Bruggeman model[J]. International Journal of Pharmaceutics: X, 3, 100079(2021).

    [13] Duvillaret L, Garet F, Coutaz J L. Highly precise determination of optical constants and sample thickness in terahertz time-domain spectroscopy[J]. Applied Optics, 38, 409-415(1999).

    [14] Silfsten P, Kontturi V, Ervasti T et al. Kramers-Kronig analysis on the real refractive index of porous media in the terahertz spectral range[J]. Optics Letters, 36, 778-780(2011).

    [15] Smith R M, Arnold M A. Terahertz time-domain spectroscopy of solid samples: principles, applications, and challenges[J]. Applied Spectroscopy Reviews, 46, 636-679(2011).

    [16] Cao B H, Zheng D D, Fan M B et al. Efficient and reliable thickness measurement method for multilayer coatings based on terahertz time-domain spectroscopy technology[J]. Acta Optica Sinica, 42, 0112001(2022).

    [17] Wang Q S, Mu D, Zhou T Y et al. Terahertz nondestructive test of delamination defects in glass-fiber-reinforced composite materials[J]. Acta Optica Sinica, 41, 1712003(2021).

    [18] Huang N E, Shen Z, Long S R et al. The empirical mode decomposition and the Hilbert spectrum for nonlinear and non-stationary time series analysis[J]. Proceedings of the Royal Society of London Series A: Mathematical, Physical and Engineering Sciences, 454, 903-995(1998).

    [19] Markl D, Yassin S, Wilson D I et al. Mathematical modelling of liquid transport in swelling pharmaceutical immediate release tablets[J]. International Journal of Pharmaceutics, 526, 1-10(2017).

    [20] Bawuah P, Markl D, Farrell D et al. Terahertz-based porosity measurement of pharmaceutical tablets: a tutorial[J]. Journal of Infrared, Millimeter, and Terahertz Waves, 41, 450-469(2020).

    [21] Zhang H Z, He M X, Shi L L et al. Terahertz thickness measurement based on stochastic optimization algorithm[J]. Spectroscopy and Spectral Analysis, 40, 3066-3070(2020).

    [22] Juuti M, Tuononen H, Prykäri T et al. Optical and terahertz measurement techniques for flat-faced pharmaceutical tablets: a case study of gloss, surface roughness and bulk properties of starch acetate tablets[J]. Measurement Science and Technology, 20, 015301(2009).

    Tools

    Get Citation

    Copy Citation Text

    Qing Li, Mingxia He. Application of Terahertz Spectroscopy in Porosity Detection of Polyolefin Films[J]. Laser & Optoelectronics Progress, 2023, 60(9): 0930003

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Spectroscopy

    Received: Mar. 25, 2022

    Accepted: May. 12, 2022

    Published Online: May. 9, 2023

    The Author Email: He Mingxia (hhmmxx@tju.edu.cn)

    DOI:10.3788/LOP221114

    Topics