Optics and Precision Engineering, Volume. 22, Issue 11, 3012(2014)

Resonant frequency measurement system for magnetoelastic sensor based on impedance response

CHENG Peng1,2,3、*, GAO Shuang1,2, ZHANG Wen-dong1,2, and SANG Sheng-bo1,2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3[in Chinese]
  • show less
    References(13)

    [1] [1] GRIMES C A, ROY S C, RANI S, et al.. Theory, instrumentation and applications of magnetoelastic resonance sensors: a review. [J]. Sensors, 2011, 11(3): 2809-44.

    [3] [3] Ausanio G, Barone A C, Hison C, et al.. Magnetoelastic sensor application in civil buildings monitoring [J]. Sensors and Actuators A: Physical, 2005, 123-124: 290-295.

    [4] [4] Park M K, Park J W, Wikle H C, et al.. Evaluation of phage-based magnetoelastic biosensors for direct detection of Salmonella Typhimurium on spinach leaves [J]. Sensors and Actuators B: Chemical, 2013, 176: 1134-1140.

    [5] [5] SHEN W, MATHISON L C, PETRENKO V A, et al.. A pulse system for spectrum analysis of magnetoelastic biosensors [J]. Applied Physics Letters, 2010, 96(16): 163502.

    [6] [6] SHEN W, ZHANG Z, HORIKAWA S, et al.. Time domain characterization of magnetoelastic sensors: A pulse method for resonance frequency determination. [J]. The Review of Scientific Instruments, 2010, 81(8): 084702.

    [7] [7] ZENG K F, PAULOSE M, ONG K G, et al.. Frequency-domain characterization of magnetoelastic sensors: a microcontroller-based instrument for spectrum analysis using a threshold-crossing counting technique [J]. Sensors and Actuators A: Physical, 2005, 121(1): 66-71.

    [8] [8] ZENG K F, ONG K G, YANG X, et al.. Board level integrated microsystem design and associated technique for impedance analysis of resonator sensors [J]. Sensor Letters, 2006, 4: 388-397.

    [9] [9] ZHANG K W. Development of portable magnetostrictive biosensor system[D]. USA:Auburn University,2010.

    [10] [10] MUNGLE C S, ROY S C, GRIMES C A. The equation of motion, impedance, and equivalent circuit model for a magnetoelastic resonance sensor [J]. Sensor Letters, 2008, 6(3): 421-427.

    [11] [11] CHAI Y, WIKLE H C, WANG Z, et al.. Design of a surface-scanning coil detector for direct bacteria detection on food surfaces using a magnetoelastic biosensor [J]. Journal of Applied Physics, 2013, 114(10): 104504.

    CLP Journals

    [1] SUN Ying, BIAN Tian-yuan, WANG Shuo, WENG Ling, ZHANG Lu-yu. Influence of bias magnetic field on detection voltage of magnetostrictive liquid level sensor[J]. Optics and Precision Engineering, 2016, 24(11): 2783

    Tools

    Get Citation

    Copy Citation Text

    CHENG Peng, GAO Shuang, ZHANG Wen-dong, SANG Sheng-bo. Resonant frequency measurement system for magnetoelastic sensor based on impedance response[J]. Optics and Precision Engineering, 2014, 22(11): 3012

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Jan. 23, 2014

    Accepted: --

    Published Online: Dec. 8, 2014

    The Author Email: Peng CHENG (chengpeng@tyut.edu.cn)

    DOI:10.3788/ope.20142211.3012