Acta Optica Sinica, Volume. 42, Issue 10, 1012002(2022)

Radiation Standard Transfer in 232--400 nm Band Based on Solar Blind Filter Radiometer

Jiawei Li1,2、*, Hongyao Chen1、**, Liming Zhang1, Wenxin Huang1, and Xiaolong Si1
Author Affiliations
  • 1Key Laboratory of Optical Calibration and Characterization, Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei 230031, Anhui, China
  • 2University of Science and Technology of China, Hefei 230026, Anhui, China
  • show less
    References(12)

    [1] Zhou H J, Zhao M J, Jiang Y et al. Design and in-orbit performance of the Chinese environmental trace gases monitoring instrument[J]. Aerospace Shanghai, 36, 154-160(2019).

    [2] Chen F N, Fan Y Z, Hong J et al. In-flight radiation calibration of a directional polarimetric camera at visible bands onboard GF-5[J]. Acta Optica Sinica, 40, 2328001(2020).

    [3] Yang T P, Si F Q, Ping W et al. Research on cloud fraction inversion algorithm of environmental trace gas monitoring instrument[J]. Acta Optica Sinica, 40, 0901001(2020).

    [4] Liu H, Zhao W Q, Yan J Y et al. UV LED measurement and prospect[J]. China Illuminating Engineering Journal, 31, 6-10(2020).

    [5] Wang J, Luo L B. Advances in Ga2O3-based solar-blind ultraviolet photodetectors[J]. Chinese Journal of Lasers, 48, 1100001(2021).

    [6] Liu T, Jia S M. Collision avoidance algorithm for unmanned aerial vehicle group based on wireless ultraviolet communication[J]. Laser & Optoelectronics Progress, 57, 212805(2020).

    [7] Jia R, Wang F, Liu X. Design and experiment of time-sharing ultraviolet polarization imaging detection system[J]. Laser & Optoelectronics Progress, 57, 021105(2020).

    [8] Wang R, Wang S R, Li F T et al. Investigation on radiation calibration system of vacuum ultraviolet detector[J]. Acta Optica Sinica, 30, 1026-1030(2010).

    [9] Liu C M, Shi X S, Chen H D et al. Ultraviolet spectral responsivity of silicon trap detectors traceable to a cryogenic radiometer[J]. Acta Photonica Sinica, 45, 0912002(2016).

    [10] Klein R, Taubert D, Thornagel R et al. Radiometric comparison of the primary synchrotron radiation source standard metrology light source with calibrated filter radiometers in the visible and NIR spectral range[J]. Metrologia, 46, 359-366(2009).

    [11] Chen H Y, Zhang L M, Zou P et al. 400--900 nm spectral irradiance of cryogenic radiometer-based irradiance standard lamp using system level calibration method[J]. Acta Optica Sinica, 30, 3349-3353(2010).

    [12] Li J W, Chen H Y, Zhang L M et al. Development of large aperture integrating sphere radiation source in ultraviolet band[J]. Acta Optica Sinica, 41, 2012005(2021).

    Tools

    Get Citation

    Copy Citation Text

    Jiawei Li, Hongyao Chen, Liming Zhang, Wenxin Huang, Xiaolong Si. Radiation Standard Transfer in 232--400 nm Band Based on Solar Blind Filter Radiometer[J]. Acta Optica Sinica, 2022, 42(10): 1012002

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Instrumentation, Measurement and Metrology

    Received: Oct. 20, 2021

    Accepted: Dec. 14, 2021

    Published Online: May. 10, 2022

    The Author Email: Li Jiawei (jiawei19@mail.ustc.edu.cn), Chen Hongyao (hychen@aiofm.ac.cn)

    DOI:10.3788/AOS202242.1012002

    Topics