Journal of Atmospheric and Environmental Optics, Volume. 12, Issue 2, 128(2017)
Spike Detection and Removal of Raman Spectra by Method Combined Nearest Neighbor Comparison with Median Filter
[1] [1] Brewer P G,Malby G, Pasteris J D, et al. Development of a laser Raman spectrometer for deep-ocean science[J]. Deep Sea Res. P T. , 2004, 51(5): 739-753.
[2] [2] White S N, Dunk R M, Peltzer E T, et al. In situ Raman analyses of deep‐sea hydrothermal and cold seep systems (Gorda Ridge and Hydrate Ridge)[J]. Geochem., Geophy., Geosy., 2006, 7(5): 5023.
[3] [3] Du Z, Li Y, Chen J, et al. Feasibility investigation on deep ocean compact autonomous Raman spectrometer developed for in-situ detection of acid radical ions[J]. Chin. J. Oceanol. Limnol., 2015, 33(2): 545-550.
[4] [4] Zhang D M, Ben-Amotz D. Removal of cosmic spikes from hyper-spectral images using a hybrid upper-bound spectrum method[J]. Appl. Spectr., 2002, 56(1): 91-98.
[5] [5] Schulze H G, Turner R F B. A two-dimensionally coincident second difference cosmic ray spike removal method for the fully automated processing of Raman spectra[J]. Appl. Spectr., 2014, 68(2): 185-191.
[6] [6] Bussian B M, Hrdle W. Robust smoothing applied to white noise and single outlier contaminated Raman spectra[J]. Appl. Spectr., 1984, 38(3): 309-313.
[7] [7] Katsumoto Y, Ozaki Y. Practical algorithm for reducing convex spike noises on a spectrum[J]. Appl. Spectr., 2003, 57(3): 317-322.
[8] [8] Hill W, Rogalla D. Spike-correction of weak signals from charge-coupled devices and its application to Raman spectroscopy[J]. Anal. Chem., 1992, 64(21): 2575-2579.
[9] [9] Phillips G R, Harris J M. Polynomial filters for data sets with outlying or missing observations: application to charge-coupled-device-detected Raman spectra contaminated by cosmic rays[J]. Anal. Chem., 1990, 62(21): 2351-2357.
[10] [10] Schulze H G, Turner R F B. A fast, automated, polynomial-based cosmic ray spike-removal method for the high-throughput processing of Raman spectra[J]. Appl. Spectr., 2013, 67(4): 457-462.
[11] [11] Takeuchi H, Hashimoto S, Harada I. Simple and efficient method to eliminate spike noise from spectra recorded on charge-coupled device detectors[J].Appl. Spectr., 1993, 47(1): 129-131.
[12] [12] Zhang D M,Jallad K N, Ben-Amotz D. Stripping of cosmic spike spectral artifacts using a new upper-bound spectrum algorithm[J]. Appl. Spectr., 2001, 55(11): 1523-1531.
[13] [13] Behrend C J,Tarnowski C P, Morris M D. Identification of outliers in hyperspectral Raman image data by nearest neighbor comparison[J]. Appl. Spectr., 2002, 56(11): 1458-1461.
[14] [14] Zhang L, Henson M J. A practical algorithm to remove cosmic spikes in Raman imaging data for pharmaceutical applications[J]. Appl. Spectr., 2007, 61(9): 1015-1020.
[15] [15] Cappel U B, Bell I M, Pickard L K. Removing cosmic ray features from Raman map data by a refined nearest neighbor comparison method as a precursor forchemometric analysis[J]. Appl. Spectr., 2010, 64(2): 195-200.
[17] [17] Li S, Dai L K. An improved algorithm to remove cosmic spikes in Raman spectra for online monitoring[J]. Appl. Spectr., 2011, 65(11): 1300-1306.
[18] [18] Mozharov S, Nordon A, Littlejohn D, et al. Automated cosmic spike filter optimized for process Raman spectroscopy[J]. Appl. Spectr., 2012, 66(11): 1326-1333.
Get Citation
Copy Citation Text
YAN Jingwen, LI Ying, CHEN Jing, YANG Dewang, ZHENG Ronger. Spike Detection and Removal of Raman Spectra by Method Combined Nearest Neighbor Comparison with Median Filter[J]. Journal of Atmospheric and Environmental Optics, 2017, 12(2): 128
Category:
Received: Aug. 12, 2015
Accepted: --
Published Online: Mar. 29, 2017
The Author Email: Ying LI (liying@ouc.edu.cn)