Infrared and Laser Engineering, Volume. 51, Issue 12, 20220509(2022)

Performance evaluation of noise equivalent spectral radiance calibration system

Sijia Huang1, Yinlin Yuan2, Wenchao Zhai2, Xiaobing Zheng2, Zhenggang Lei3, and Yu Lin3
Author Affiliations
  • 1School of Environment Science and Optoelectronic, University of Science and Technology of China, Hefei 230026, China
  • 2Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China
  • 3Kunming Institute of Physics, Kunming 650223, China
  • show less
    References(18)

    [1] [1] Lu Wanzhen, Yuan Hongfu, Xu Guangtong. Modern Near Infrared Spectroscopy Technology [M]. Beijing: China Petrochemical Press, 2000: 3745. (in Chinese)

    [2] J H Li, F Xue, L Xue, et al. Performance test of fourier transform infrared imaging spectrometer. Optics and Precision Engineering, 23, 201-207(2015).

    [4] [4] Rentz J H, Engel J R. Passive spectroradiometer calibration: Radiance responsivity, sensitivity, radiation reference [C]Fourier Transfm Spectroscopy: New Methods Applications, OSA Technical Digest, 1999: FWE13.

    [5] [5] Song Jian. Research on the traceability the onbit emissivity measurement method of space primary stard blackbody[D]. Beijing: University of Chinese Academy of Sciences, 2019. (in Chinese)

    [6] Xiaopeng Hao, Jian Song, Jianping Sun, et al. Vacuum radiance temperature national standard facility for Infrared remote sensors of Chinese Fengyun meteorological satellites. Optics and Precision Engineering, 23, 1845-1851(2015).

    [7] [7] Kaplan S G, Woods S I, Carter A C. Calibration of IR test chambers with the missile defense transfer radiometer [C]Proceedings of SPIE, 2013, 8707: 870709.

    [8] [8] Jung T M, Carter A C, Woods S I. Calibration deployment of a new NIST transfer radiometer f broadb spectral calibration of space chambers (MDXR) [C]Proceedings of SPIE, 2011, 8015: 80150C.

    [9] [9] Chamberl M, Farley V, Giroux J, et al. Development testing of a hyperspectral imaging instrument f field spectroscopy [C]Proceedings of SPIE, 2004, 5546: 1936.

    [10] Mengya Zhang, Yinlin Yuan, Wenchao Zhai, et al. Design and test of infrared integrating sphere radiation source with wide dynamic range. Acta Optica Sinica, 39, 0612006(2019).

    [11] Sijia Huang, Yinlin Yuan, Wenchao Zhai, et al. Design optimization and performance test of infrared integrating sphere radiation source with wide dynamic range (Invited). Infrared and Laser Engineering, 50, 20210516(2021).

    [12] [12] Li Xunniu, Zheng Weijian, Lei Zhenggang, et al. Analysis f signaltonoise ratio of hyperspectral imaging FTIR interferometer [C]Proceedings of SPIE, 2013, 8910: 89101P.

    [13] Weijian Zheng, Weiqi Jin, Junhong Su. NESR of long-distance passive infrared telemetering systems. Infrared Technology, 29, 512-514(2007).

    [14] H E Revercomb, H Buijs, B Hugh, al at. Radiometric calibration of IR Fourier transform spectrometers: Solution to a problem with the high-resolution interferometer sounder. Applied Optics, 27, 3210-3218(1988).

    [15] Dandan Wei, Fuping Gan, Zhenhua Zhang, et al. A study of SNR index setting of infrared imager based on spectrum simulation. Remote Sensing for Land & Resources, 28, 18-23(2016).

    [16] [16] Wurst N P, Meola J, Perry D L, et al. Measurement modeling of longwave infrared directional downwelling spectral radiance [C]Proceedings of SPIE, 2015, 9611: 96110X.

    [17] [17] Farley V, Villemaire A, Martin C, et al. Perfmance of the FIRST, a longwave infrared hyperspectral imaging sens [C]The International Society f Optical Engineering, Proceedings of SPIE, 2006, 6398: 689487.

    [18] [18] Villemaire A, Martin C, Giroux J, et al. Radiometric calibration of FTIR remote sensing instrument [C]Proceedings of SPIE, 1997, 3082: 8691.

    [19] [19] Liu Zhimin, Liu Feng. Evaluation Expression of Uncertainty in Measurement JJF1059.12012 [S]. Beijing: General Administration of Quality Supervision, Inspection Quarantine of the People''s Republic of China, 2012. (in Chinese)

    Tools

    Get Citation

    Copy Citation Text

    Sijia Huang, Yinlin Yuan, Wenchao Zhai, Xiaobing Zheng, Zhenggang Lei, Yu Lin. Performance evaluation of noise equivalent spectral radiance calibration system[J]. Infrared and Laser Engineering, 2022, 51(12): 20220509

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Infrared technology and application

    Received: Jul. 21, 2022

    Accepted: --

    Published Online: Jan. 10, 2023

    The Author Email:

    DOI:10.3788/IRLA20220509

    Topics