Chinese Optics Letters, Volume. 18, Issue 12, 121703(2020)

Design and implementation of the galvanometer scanning system for reflectance confocal and stimulated Raman scattering microscopy

Fangyu Wang1,2,3,4, Yuhao Yuan4, Qiang Sun1, Ming Dai1, Li Ai5,6, and Fake Lu4、*
Author Affiliations
  • 1Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
  • 2University of Chinese Academy of Sciences, Beijing 100049, China
  • 3Jilin Yataizhongke Medical Equipment Engineering Technology Research Institute Holding Co., Ltd., Changchun 130000, China
  • 4Department of Biomedical Engineering, Binghamton University, State University of New York, Binghamton, NY 13902, USA
  • 5Jilin Provincial Key Laboratory of Photoelectric Equipment and Instrument Advanced Manufacture Technology, Changchun 130033, China
  • 6Changchun UP Optotech Holding Co., Ltd., Changchun 130033, China
  • show less
    References(15)
    Cited By
    Tools

    Get Citation

    Copy Citation Text

    Fangyu Wang, Yuhao Yuan, Qiang Sun, Ming Dai, Li Ai, Fake Lu. Design and implementation of the galvanometer scanning system for reflectance confocal and stimulated Raman scattering microscopy[J]. Chinese Optics Letters, 2020, 18(12): 121703

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Biophotonics

    Received: May. 20, 2020

    Accepted: Aug. 11, 2020

    Published Online: Oct. 9, 2020

    The Author Email: Fake Lu (fakelu@binghamton.edu)

    DOI:10.3788/COL202018.121703

    Topics