Chinese Journal of Lasers, Volume. 45, Issue 2, 207001(2018)

Implantable Optoelectronic Devices and Systems for Biomedical Application

Shi Zhao1, Li Lizhu1, Zhao Yu1, Fu Ruxing2, and Sheng Xing1、*
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    References(169)

    [2] Parashurama N. O'Sullivan T D, de La Zerda A, et al. Continuous sensing of tumor-targeted molecular probes with a vertical cavity surface emitting laser-based biosensor[J]. Journal of Biomedical Optics, 17, 345-352(2012).

    [5] Bellis S, Jackson J C, Mathewson A. Towards a disposable in vivo miniature implantable fluorescence detector[C]. SPIE, 6083, 60830N(2006).

    [17] Bingger P, Fiala J, Seifert A et al. In vivo monitoring of blood oxygenation using an implantable MEMS-based sensor[C]. IEEE 23rd International Conference on Micro Electro Mechanical Systems (MEMS), 1031-1034(2010).

    [18] Keiser G. Optical fiber communications[M]. New York: John Wiley & Sons(2003).

    [19] Jacques S L. Corrigendum: optical properties of biological tissues: a review[J]. Physics in Medicine and Biology, 58, 5007-5008(2013).

    [20] Deisseroth K. Optogenetics[J]. Nature Methods, 8, 26-29(2011).

    [44] Tao H, Kainerstorfer J M, Siebert S M et al. Implantable, multifunctional, bioresorbable optics[J]. Proceedings of the National Academy of Sciences of United States of America, 109, 19584-19589(2012).

    [51] Chang C Y, Kai F. GaAs high-speed devices[M]. New York: John Wiley & Sons(1994).

    [54] Kim D H, Kim Y S, Wu J et al. Ultrathin silicon circuits with strain-isolation layers and mesh layouts for high-performance electronics on fabric, vinyl, leather, and paper[J]. Advanced Materials, 21, 3703-3707(2009).

    [62] Khang D Y, Jiang H Q, Huang Y et al. A stretchable form of single-crystal silicon for high-performance electronics on rubber substrates[J]. Science, 311, 208-212(2006).

    [65] Kim T H, Carlson A, Ahn J H et al. Kinetically controlled, adhesiveless transfer printing using microstructured stamps[J]. Applied Physics Letters, 94, 113502(2009).

    [78] Pisanello F, Sileo L, Patria A D et al. Multipoint optogenetic control of neural activity with tapered and nanostructured optical fibers[C]. IEEE Microwave Symposium, 1-4(2016).

    [79] Szabo V. Optogenetics in freely behaving mice with a fiberscope[D]. Paris: Paris DescartesUniversity(2013).

    [81] Murari K, Etienne-Cummings R, Cauwenberghs G et al. An integrated imaging microscope for untethered cortical imaging in freely-moving animals[C]. Engineering in Medicine and Biology Society (EMBC), 5795-5798(2010).

    [83] Wang S, Buch A, Hussaini S A et al. Focused ultrasound facilitated adenoviral delivery for optogenetic stimulation[C]. Ultrasonics Symposium, 1-4(2015).

    [119] Yu Y, Crothall K D, Jahn L G et al. Laser diode applications in a continuous blood glucose sensor[C]. SPIE, 4996, 268-274(2003).

    [121] Khan F, Gnudi L, Pickup J C. Fluorescence-based sensing of glucose using engineered glucose/galactose-binding protein: a comparison of fluorescence resonance energy transfer and environmentally sensitive dye labelling strategies[J]. Biochemical and Biophysical Research Communications, 365, 102-106(2008).

    [123] Chaudhary A. McShane M J, Srivastava R. Glucose response of dissolved-core alginate microspheres: towards a continuous glucose biosensor[J]. Analyst, 135, 2620-2628(2010).

    [126] Shibata H, Tsuda Y, Kawanishi T et al. Implantable fluorescent hydrogel for continous blood glucose monitoring[C]. Solid-State Sensors, Actuators and Microsystems Conference, 1453-1456(2009).

    [136] Webb R K, Ralston A C, Runciman W B. Potential errors in pulse oximetry[J]. Anaesthesia, 46, 207-212(1991).

    [147] O'Sullivan T. Munro E A, Parashurama N, et al. Implantable semiconductor biosensor for continuous in vivo sensing of far-red fluorescent molecules[J]. Optics Express, 18, 12513-12525(2010).

    [148] O'Sullivan T D. Munro E, de la Zerda A, et al. Implantable optical biosensor for in vivo molecular imaging[C]. SPIE, 7173, 717309(2009).

    [151] Tagawa A, Minami H, Mitani M et al. 49(1S): 01AG02[J]. electrical potential in deep brain of mouse. Japanese Journal of Applied Physics(2010).

    [164] Bernstein J G, Han X, Henninger M A et al. Prosthetic systems for therapeutic optical activation and silencing of genetically-targeted neurons[C]. SPIE, 6854, 68540H(2008).

    [167] Arthur W B. The nature of technology: what it is and how it evolves[M]. New York: Simon and Schuster(2009).

    [170] Bansal A K, Hou S, Kulyk O et al. Wearable organic optoelectronic sensors for medicine[J]. Advanced Materials, 27, 7638-7644(2015).

    Tools

    Get Citation

    Copy Citation Text

    Shi Zhao, Li Lizhu, Zhao Yu, Fu Ruxing, Sheng Xing. Implantable Optoelectronic Devices and Systems for Biomedical Application[J]. Chinese Journal of Lasers, 2018, 45(2): 207001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Special Issue:

    Received: Sep. 12, 2017

    Accepted: --

    Published Online: Feb. 28, 2018

    The Author Email: Xing Sheng (xingsheng@tsinghua.edu.cn)

    DOI:10.3788/CJL201845.0207001

    Topics