Optics and Precision Engineering, Volume. 30, Issue 22, 2839(2022)

Distortion analysis and focal length testing of off-axis optical system

Qiang CHENG1、*, Haixiang HU1, Longxiang LI1, Xiaokun WANG1, Xiao LUO1, and Xuejun ZHANG1,2
Author Affiliations
  • 1Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Key Laboratory of Optical System Advanced Manufacturing Technology, Changchun30033, China
  • 2University of Chinese Academy of Sciences, Beijing100049, China
  • show less
    Figures & Tables(5)
    Distortion measurement schematic diagram
    Corresponding relationship between feature points on each detector and ground object coordinates
    • Table 1. Comparison between equivalent focal length calculated by the fifth order distortion coefficient and ZEMAX ray tracing results

      View table
      View in Article

      Table 1. Comparison between equivalent focal length calculated by the fifth order distortion coefficient and ZEMAX ray tracing results

      离轴角Y/(°)视场角X/(°)方向五阶畸变系数/mmZEMAX光线追迹/mm绝对偏差/mm
      3.960X8 836.9908 836.9830.007
      Y9 019.1329 019.185-0.053
      3.960.5X8 841.3668 841.3400.026
      Y9 020.8579 020.887-0.03
      3.961X8 854.5598 854.4530.106
      Y9 026.0469 026.0090.037
      3.961.5X8 876.7568 876.5140.242
      Y9 034.7409 034.5960.144
      3.961.75X8 891.3238 891.447-0.124
      Y9 040.4229 040.688-0.266
      4.330X8 855.0218 855.0170.004
      Y9 076.5849 076.771-0.187
      4.330.5X8 859.4788 859.787-0.309
      Y9 078.3889 078.554-0.166
      4.331X8 872.9108 872.7900.12
      Y9 083.8169 083.920-0.104
      4.331.5X8 895.5088 895.2350.273
      Y9 092.9099 092.917-0.008
      4.331.75X8 910.3368 909.9700.366
      Y9 098.8519 098.8030.048
    • Table 2. Object two dimension angle and actual image height data table on grid plate

      View table
      View in Article

      Table 2. Object two dimension angle and actual image height data table on grid plate

      序号物方角度/(°)实际像高数据/mm
      XYXY
      14.237-1.532 8656.761-237.195
      23.983-1.194 7615.960-184.485
      34.240-0.852 6656.760-131.775
      43.985-0.512 5615.961-79.065
      54.241-0.170 6656.759-26.355
      63.9840.170 8615.96226.355
      74.2390.511 7656.76179.065
      83.9850.853 8615.961131.775
      94.2421.193 0656.762184.485
      103.9821.535 2615.960237.195
    • Table 3. Coordinates of three feature points on each detector

      View table
      View in Article

      Table 3. Coordinates of three feature points on each detector

      探测器序号特征点1特征点2特征点3
      1(-210.315,667.8)(-237.195,667.8)(-264.075,667.8)
      2(-157.605,627)(-184.485,627)(-211.365,627)
      3(-104.895,667.8)(-131.775,667.8)(-158.665,667.8)
      4(-52.185,627)(-79.065,627)(-105.945,627)
      5(0.525,667.8)(-26.355,667.8)(-53.235,667.8)
      6(53.235,627)(26.355,627)(-0.525,627)
      7(105.945,667.8)(79.065,667.8)(52.185,667.8)
      8(158.655,627)(131.775,627)(104.895,627)
      9(211.365,667.8)(184.485,667.8)(157.605,667.8)
      10(264.075,627)(237.195,627)(210.315,627)
    Tools

    Get Citation

    Copy Citation Text

    Qiang CHENG, Haixiang HU, Longxiang LI, Xiaokun WANG, Xiao LUO, Xuejun ZHANG. Distortion analysis and focal length testing of off-axis optical system[J]. Optics and Precision Engineering, 2022, 30(22): 2839

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Modern Applied Optics

    Received: Apr. 25, 2022

    Accepted: --

    Published Online: Nov. 28, 2022

    The Author Email: CHENG Qiang (chengq@ciomp.ac.cn)

    DOI:10.37188/OPE.20223022.2839

    Topics