High Power Laser and Particle Beams, Volume. 32, Issue 2, 025013(2020)

Status of radiographic X-ray source driven by 4 MV, 80 kA induction voltage adder

Hao Wei... Jiahui Yin, Pengfei Zhang, Fengju Sun, Aici Qiu, Tianxue Liang, Jiangtao Zeng, Xiaofeng Jiang, Zhiguo Wang, Jiang Sun, Wenyuan Liu and Yixiang Hu |Show fewer author(s)
Author Affiliations
  • State Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology, Xi'an 710024, China
  • show less
    Figures & Tables(12)
    4 MV IVA facility developed for flash X-ray radiography
    Cutoff view of a deionized-water coaxial line水介质传输线示意图
    Illustration of cavity used in Jianguang-II“剑光二号”感应腔
    Potential distribution in the last cavity末级感应腔电势分布
    Sketch of the vacuum transmission line for the Jianguang-II facility“剑光二号”真空传输线示意图
    Measured outputs of the prime power source实测前级脉冲源输出波形
    Measured IVA output voltage and diode current装置输出电压和二极管电流
    Diode voltage based on the inductive correction基于电感修正方法获得二极管电压
    Calculated dynamic impedance of RPD and measured X-ray waveforms二极管动态阻抗和X射线波形
    Original image of the X-ray spot obtained by pinhole imaging technique针孔成像法测量X射线焦斑
    • Table 1. Key output parameters of the Jianguang-II facility over a ten shot sequence

      View table
      View in Article

      Table 1. Key output parameters of the Jianguang-II facility over a ten shot sequence

      shotoutput voltage/MVrisetime/nsdiode current/kAX-ray FWHM time/nsdose@1 m/rad(LiF)delay time/ns
      2019-0174.32285.35814.8748
      2019-0184.62484.15415.7749
      2019-0194.52085.65616.0748
      2019-0204.52080.55414.5745
      2019-0214.42486.25616.1740
      2019-0223.92084.95814.2741
      2019-0234.52184.25315.6748
      2019-0244.21987.05215.4756
      2019-0254.31788.05216.9756
      2019-0264.22182.55215.4762
      average4.3±0.221±2.184.8±2.255±2.415.5±0.8749±7
    • Table 2. Comparation of output parameters between the Jianguang-I and Jianguang-II facilities

      View table
      View in Article

      Table 2. Comparation of output parameters between the Jianguang-I and Jianguang-II facilities

      output voltage/MVdiode current/kAX-ray FWHM time/nsradiated dose @1 m/rad(LiF)spot diameter/mm
      Jianguang-I facility2.451463.71
      Jianguang-II facility4.3855515.51.4
    Tools

    Get Citation

    Copy Citation Text

    Hao Wei, Jiahui Yin, Pengfei Zhang, Fengju Sun, Aici Qiu, Tianxue Liang, Jiangtao Zeng, Xiaofeng Jiang, Zhiguo Wang, Jiang Sun, Wenyuan Liu, Yixiang Hu. Status of radiographic X-ray source driven by 4 MV, 80 kA induction voltage adder[J]. High Power Laser and Particle Beams, 2020, 32(2): 025013

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Sep. 3, 2019

    Accepted: --

    Published Online: Mar. 18, 2020

    The Author Email:

    DOI:10.11884/HPLPB202032.190331

    Topics