Optics and Precision Engineering, Volume. 21, Issue 9, 2272(2013)
Molecularly imprinted sensor integrated with thin-film bulk acoustic resonator for drug detection
[1] [1] HAO H X, LIU J J, WEI T X. Application of molecular imprinting technique in drug detection [J]. Chin. J. Forensic Med., 2009, 24(5): 315-317. (in Chinese)
[2] [2] TOKONAMI S, SHIIGI H, NAGAOKA T. Review: Micro-and nanosized molecularly imprinted polymers for high-throughput analytical applications [J]. Analytica chimica acta, 2009, 641(1): 7-13.
[3] [3] COOPER M A, SINGLETON V T. A survey of the 2001 to 2005 quartz crystal microbalance biosensor literature: applications of acoustic physics to the analysis of biomolecular interactions [J]. Journal of Molecular Recognition, 2007, 20(3): 154-184.
[4] [4] FU Y Q, LUO J K, DU X Y, et al.. Recent developments on ZnO films for acoustic wave based bio-sensing and microfluidic applications: a review [J]. Sensors and Actuators B: Chemical, 2010, 143(2): 606-619.
[6] [6] LIN R C, CHEN Y C, CHANG W T, et al.. Highly sensitive mass sensor using film bulk acoustic resonator [J]. Sensors and Actuators A: Physical, 2008, 147(2): 425-429.
[7] [7] KANDIMALLA V B, JU H. Molecular imprinting: a dynamic technique for diverse applications in analytical chemistry [J]. Anal Bioanal Chem., 2004, 380(4): 587-605.
[8] [8] TOAL S J, TROGLER W C. Polymer sensors for nitroaromatic explosives detection[J]. J. Mater. Chem., 2006, 16(28): 2871-2883.
[9] [9] ZHANG H. Micromachined Bulk Acoustic Resonators for Radio-frequecy Systems and Biochem Mass sensing[D].California: University of Southern California, 2006.
[10] [10] CHU H Q, WU G M, CHEN J M, et al.. Design and simulation of self-powered radio frequency identification (RFID) tags for mobile temperature monitoring [J]. Sci. China Tech., 2013, 56(1): 1-7.
[11] [11] FU J ZH, HE Y, CHEN Z CH. Research on soft-sening of fluid temperature in microfluidic chip [J]. Opt. Precision Eng., 2004, 12(3): 140-143. (in Chinese)
[12] [12] VOGT B D, LIN E K, WU W, et al.. Effect of film thickness on the validity of the sauerbrey equation for hydrated polyelectrolyte films [J]. The Journal of Physical Chemistry B, 2004, 108(34): 12685-12690.
[13] [13] LI K. A Study on Thin Film Bulk Acoustic Resonator (FBAR) for Mass Sensor Application[D]. Hangzhou: Zhejiang University, 2011.(in Chinese)
Get Citation
Copy Citation Text
CHEN Jian-ming, Lv Qi-meng, WU Guang-min, CHU He-qun, John D Mai. Molecularly imprinted sensor integrated with thin-film bulk acoustic resonator for drug detection[J]. Optics and Precision Engineering, 2013, 21(9): 2272
Category:
Received: May. 2, 2013
Accepted: --
Published Online: Sep. 25, 2013
The Author Email: Jian-ming CHEN (jmchen@inems.com)