Laser & Optoelectronics Progress, Volume. 58, Issue 9, 0906002(2021)

High-Voltage Bushing Test of FBG Three-Dimensional Tension Sensor in Substation

Kai Xie1,2, Tao Tan1,2, Xuezhen Si1, Lü Zhongbin1, Pengliang Ren1, Xianghe Liu2, Chao Duan2, Ye Tian2, Quan Chai2, Fei Gao3, and Jianzhong Zhang2、*
Author Affiliations
  • 1Henan Electric Power Corporation Electric Power Research Institute, State Grid, Zhengzhou , Henan 450002, China
  • 2Key Laboratory of In-Fiber Integrated Optics, Ministry of Education, Harbin Engineering University, Harbin , Heilongjiang 150001, China
  • 3Systems Engineering Research Institute of China State Shipbuilding Cooperation, Beijing 100094, China
  • show less
    References(25)

    [1] Zhang X Z. Study on the mechanical performance of down line and terminals of ultra-high voltage bushings[D], 1-8(2018).

    [2] Peng Q. Main transformer 500 kV high-voltage bushing explosion analysis of Guohua Taishan power plant[J]. Shenhua Science and Technology, 7, 62-65(2009).

    [3] Kong Y, Wen Z, Zhao G P et al. Analyses on the problems of air-terminal deformation of bushings about our domestic 1000 kV project[J]. Engineering and Technological Research, 117-119(2019).

    [4] Sikorski W, Siodla K, Moranda H et al. Location of partial discharge sources in power transformers based on advanced auscultatory technique[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 19, 1948-1956(2012).

    [5] Stone G C. Partial discharge diagnostics and electrical equipment insulation condition assessment[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 12, 891-904(2005).

    [6] Xu C S, Sun Z Q, Zhang G J. On-line and on-site PD monitoring and diagnosis of power transformer[C], 293-296(2012).

    [7] Sun Q, Huang Z J, Han S Z et al. Analysis on an insulation accident of 800 kV high voltage bush[J]. Power System and Clean Energy, 26, 12-15(2010).

    [8] Du Z B, Nie D X, Zhang L X et al. Insulation evaluation of high voltage bushing based on frequency domain spectroscopy analysis[J]. High Voltage Apparatus, 49, 6-11(2013).

    [9] Bellorini S, Salvetti M, Bettinali F et al. Seismic qualification of transformer high voltage bushings[J]. IEEE Transactions on Power Delivery, 13, 1208-1213(1998).

    [10] Wu W. A type of terminal[P].

    [11] Yu K W, Liang X Y, Tang H Z et al. Stress analysis of bushing studs in high-voltage side of UHV transformer under two different connection modes[J]. Sichuan Electric Power Technology, 40, 44-47(2017).

    [12] Qiu N, Liu Z L, He Y J et al. Force simulation and test of ultra high voltage transformer bushing terminal in wind load[J]. Science Technology and Engineering, 19, 181-187(2019).

    [13] Lü Z B, Xie K, Zhang X Z et al. Analysis on static mechanical characteristics of down lead transmission lines and connecting fittings in ultra high voltage substation[J]. High Voltage Apparatus, 53, 30-37(2017).

    [14] Qian S L, Lü Z B, Kou X S et al. Three-dimensional force sensor of a transformer high-tension bushing tip style of calligraphy gold utensil[P].

    [15] Zhang J G, Qian S L, Xie K et al. Three-dimensional force sensor of transformer high-tension bushing tip goat's horn type gold utensil[P].

    [16] Zhu Q R, Xu C, Yang G B. Experimental research on damage detecting in composite materials with FBG sensors under low frequency cycling[J]. International Journal of Fatigue, 101, 61-66(2017).

    [17] Wen B R, Tian X L, Jiang Z H et al. Monitoring blade loads for a floating wind turbine in wave basin model tests using fiber Bragg grating sensors: a feasibility study[J]. Marine Structures, 71, 102729(2020).

    [18] Kim J M, Kim C M, Choi S Y et al. Enhanced strain measurement range of an FBG sensor embedded in seven-wire steel strands[J]. Sensors, 17, 1654(2017).

    [19] Chen J, Guo Y X, Zhu F D et al. Fiber Bragg grating inclination sensor for transmission tower[J]. Laser & Optoelectronics Progress, 56, 080602(2019).

    [20] Chen J, Guo Y X, Zhang L P. A glass-fiber packaged fiber Bragg grating strain sensor[J]. Laser & Optoelectronics Progress, 57, 090601(2020).

    [21] Wang Y H, Zhang M Y, Ma J X et al. Measurements of penetration characteristics of jacked piles in clayey soil based on fiber Bragg gratings[J]. Acta Optica Sinica, 40, 0706004(2020).

    [22] Jiang L, Zhang X Z, Wang J et al. Real-time online detection of cutter wear based on fiber Bragg grating array[J]. Acta Optica Sinica, 39, 1206003(2019).

    [23] Wei L, Yu L L, Jiang D Z et al. Fiber Bragg grating accelerometer based on diaphragm and diamond structure[J]. Chinese Journal of Lasers, 46, 0910003(2019).

    [24] Chen Y, Chen Y W, Liu Z Q et al. A gear fault detection method based on a fiber Bragg grating sensor[J]. Chinese Journal of Lasers, 47, 0304007(2020).

    [25] Hill K O, Meltz G. Fiber Bragg grating technology fundamentals and overview[J]. Journal of Lightwave Technology, 15, 1263-1276(1997).

    Tools

    Get Citation

    Copy Citation Text

    Kai Xie, Tao Tan, Xuezhen Si, Lü Zhongbin, Pengliang Ren, Xianghe Liu, Chao Duan, Ye Tian, Quan Chai, Fei Gao, Jianzhong Zhang. High-Voltage Bushing Test of FBG Three-Dimensional Tension Sensor in Substation[J]. Laser & Optoelectronics Progress, 2021, 58(9): 0906002

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Fiber Optics and Optical Communications

    Received: Jul. 30, 2020

    Accepted: Sep. 20, 2020

    Published Online: May. 12, 2021

    The Author Email: Zhang Jianzhong (zhangjianzhong@hrbeu.edu.cn)

    DOI:10.3788/LOP202158.0906002

    Topics