Journal of Applied Optics, Volume. 42, Issue 5, 848(2021)
Calibration of multiple cameras based on ChArUco board
A multiple cameras calibration method based on chess augmented reality university of cordoba (ChArUco) board was proposed for the multiple cameras system with limited or non-overlapping field of view. The ChArUco board was used to calibrate the camera; the global optimization was carried out based on the binocular reprojection error to provide precision guarantee for the subsequent pose transfer between cameras with non-overlapping field of view. Finally, the performance was tested by the spatial point reconstruction. The experimental results show that the average measurement error is 0.11 % within the point distance of 25 cm.
Get Citation
Copy Citation Text
Ziliang ZHAO, Zonghua ZHANG, Nan GAO, Zhaozong MENG. Calibration of multiple cameras based on ChArUco board[J]. Journal of Applied Optics, 2021, 42(5): 848
Category: OE INFORMATION ACQUISITION AND PROCESSING