Optics and Precision Engineering, Volume. 20, Issue 1, 38(2012)

Design and test of force actuator in active optical system

ZHANG Li-min*... ZHANG Bin, YANG Fei and MING Ming |Show fewer author(s)
Author Affiliations
  • [in Chinese]
  • show less
    References(10)

    [1] [1] YU Y, CAO G R. A study on the corrective capability and optimization of active mirrors[J].Transactions of Beijing Institute of Technology,2003, 23(2): 229-233.

    [2] [2] SU D Q, CUI X Q. Active optics- key technology of the new generation telescopes [J]. Progress in Astronomy, 1999,17(1): 1-14. (in Chinese)

    [3] [3] CHENG J X. Principles of Astronomical Telescope Design [M].Beijing: Chinese Science & Technology Press, 2002. (in Chinese)

    [4] [4] MASANORI L, KEIICHI K. Primary mirror support system for the SUBARU telescope[J]. SPIE, 1994,2199: 762-772.

    [5] [5] CONRAD N, ZOLCINSKI-COUET M C, MICHAEL K. The active primary mirror system for the SOAR telescope[J]. SPIE, 2004,5489: 870-880.

    [6] [6] JAMES E K, DAVID Gr .AEOS 3.67 m telescope primary mirror active control system[J]. SPIE, 1998, 3352: 400-411.

    [7] [7] YORKE J, Br, JON D. Improvements to the Apache Point 3.5 meter primary mirror support system. SPIE, 1998,3351: 172-177.

    [9] [9] LIU Z J. Application Manual of Rolling Bearing [M].Beijing: China Machine Press, 2006. (in Chinese)

    [10] [10] LI H Z, LIN X D, LIU X Y, et al.. Experiment system of 400 mm thin-mirror active optics [J]. Opt. Precision Eng., 2009, 17(9): 2077: 2076-2083. (in Chinese)

    CLP Journals

    [1] An Qichang, Zhang Jingxu, Yang Fei, Zhang Kexin. Sub-aperture stitching algorithm based on structure function[J]. Infrared and Laser Engineering, 2015, 44(3): 929

    [2] Li Hongzhuang, Zhang Zhenduo, Wang Jianli, Liu Xinyue, Wu Xiaoxia, Zhang Limin, Zhang Bin, Wang Liang. Active Surface-Profile Correction of 620 mm Thin-Mirror Based on Flotation Support[J]. Acta Optica Sinica, 2013, 33(5): 511001

    [3] An Qichang, Zhang Jingxu, Yang Fei. Area Structural Function Collapse with Randon Transformation[J]. Acta Optica Sinica, 2014, 34(4): 423001

    [4] ZHANG Yu-fang, LI Guo-ping. Design of voice coil force actuator in thin mirror active optical system[J]. Optics and Precision Engineering, 2013, 21(11): 2836

    [5] WANG Fu-guo, AN Qi-chang. Evaluation of mirror surface figures for TMT based on SlopeRms[J]. Optics and Precision Engineering, 2014, 22(5): 1171

    [6] YANG Fei, LIU Guo-jin, AN Qi-chang. Error allocation of opto-mechanical system for large aperture telescope based on structure function[J]. Optics and Precision Engineering, 2015, 23(1): 117

    [7] ZHANG Jing-xu, AN Qi-chang, LI Jian-feng, YANG Fei. Third mirror Stewart platform of TMT based on mechanism condition number[J]. Optics and Precision Engineering, 2014, 22(4): 890

    Tools

    Get Citation

    Copy Citation Text

    ZHANG Li-min, ZHANG Bin, YANG Fei, MING Ming. Design and test of force actuator in active optical system[J]. Optics and Precision Engineering, 2012, 20(1): 38

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Jan. 20, 2011

    Accepted: --

    Published Online: Feb. 14, 2012

    The Author Email: Li-min ZHANG (zhangtqx@163.com)

    DOI:10.3788/ope.20122001.0038

    Topics