Acta Optica Sinica, Volume. 40, Issue 5, 0512002(2020)

Three-Point Light Pen Space Coordinate Measurement Based on Light Field Epipolar Plane Image Ranging

Jun Wu1,2、*, Zechuan Li1, Jianwen Zheng1, Jun Xu1, and Zhijing Yu3
Author Affiliations
  • 1College of Aeronautical Engineering, Civil Aviation University of China, Tianjin 300300, China
  • 2State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China
  • 3College of Electronic Information and Automation, Civil Aviation University of China, Tianjin 300300, China
  • show less
    Figures & Tables(13)
    Imaging schematic of light field camera
    EPI obtained by light field camera
    Epipolar geometry
    Diagram of slope of diagonal line in EPI
    Schematic of SPO
    Schematic of P3P projection
    Experiment system
    Flow chart of measurement system
    SPO depth label image
    Design image of light pen
    • Table 1. Comparison test along the X-axis directionmm

      View table

      Table 1. Comparison test along the X-axis directionmm

      Translation stage reference data50100150200
      Measurement valueMaximum50.345100.846150.754199.896
      Minimum49.772100.341149.924199.123
      Average50.138100.554150.534199.423
      Correct rate (compared with reprojection results)TrueTrueTrueTrue
    • Table 2. Comparison test along the Y-axis directionmm

      View table

      Table 2. Comparison test along the Y-axis directionmm

      Translation stage reference data50100150200
      Measurement valueMaximum50.634100.565150.322200.396
      Minimum49.82499.788149.860200.044
      Average50.445100.245150.220200.254
      Correct rate (compared with reprojection results)TrueTrueTrueTrue
    • Table 3. Comparison test along the Z-axis directionmm

      View table

      Table 3. Comparison test along the Z-axis directionmm

      Translation stage reference data50100150200
      Measurement valueMaximum50.533100.523150.436200.555
      Minimum49.982100.144149.926200.021
      Average50.322100.322150.283200.321
      Correct rate (compared with reprojection results)TrueTrueTrueTrue
    Tools

    Get Citation

    Copy Citation Text

    Jun Wu, Zechuan Li, Jianwen Zheng, Jun Xu, Zhijing Yu. Three-Point Light Pen Space Coordinate Measurement Based on Light Field Epipolar Plane Image Ranging[J]. Acta Optica Sinica, 2020, 40(5): 0512002

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Instrumentation, Measurement and Metrology

    Received: Sep. 25, 2019

    Accepted: Nov. 9, 2019

    Published Online: Mar. 10, 2020

    The Author Email: Wu Jun (j_wu@cauc.edu.cn)

    DOI:10.3788/AOS202040.0512002