    Figures & Tables(13)
    Schematic diagram of common calibration board
    Schematic diagram of multi-position combination transit pose calibration
    Experimental platform of combined vision measurement system
    LCS measurement error absolute value and average error
    Fixed target base and target balls
    Line diagram of multi-position single-point coupling calibration error absolute value
    Line diagram of multi-position and multi-point coupling calibration error absolute value
    Standard spacing of mark points at both ends of a standard bar
    Multi-position single point coupling calibration combined measurement error
    Multi-positions multi-point coupling calibration combined measurement error
    • Table 1. Internal and external parameters and distortion coefficients of LCS systems

      View table
      View in Article

      Table 1. Internal and external parameters and distortion coefficients of LCS systems

      LCS systemIntrinsic parameterDistortion coefficientExtrinsic parameters
      Left Camera2520.280666.5302519.64494.38001-0.096 50.593 9-0.000 33  0.001 29-2.012 7R=    0.815 8    0.058 6    0.575 3-0.054 5    0.998 2-0.024 3-0.575 7-0.011 5    0.817 6
      Right Camera2545.520630.7802545.32516.04001     -0.099      0.475 4-0.001 22-0.001 08     -1.476T=-334.099.243115.87
    • Table 2. Three-dimensional coordinates of three-point target ball measured by laser tracker

      View table
      View in Article

      Table 2. Three-dimensional coordinates of three-point target ball measured by laser tracker

      PointXYZ
      P11 608.631 4-677.280 8-100.613 0
      P21 624.353 6-764.594 2-104.755 6
      P31 606.240 3-678.687 1-37.339 7
    • Table 3. Results of multi-position single-point coupling and multi-position multi-point coupling

      View table
      View in Article

      Table 3. Results of multi-position single-point coupling and multi-position multi-point coupling

      M6DLCR6DLCT6DLC/mm
      Single point solution-0.480 1-0.114 3-0.868 4    0.874 8-0.056 0-0.478 6    0.001 3-0.994 3    0.131 9    79.419-106.34-258.42
      Multipoint coupled solution-0.480 8-0.115 7-0.869 1    0.875 6-0.061 8-0.476 1    0.001 2-0.994 3    0.131 4    79.746-107.53-258.26
    Tools

    Get Citation

    Copy Citation Text

    Renchuan YANG, Haihua CUI, Xifu ZHAO, Ronghui GUO, Tao JIANG. Multi-pose coupled transformation calibration for combined tracking-based optical measurement[J]. Optics and Precision Engineering, 2024, 32(17): 2686

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Precision Measurement and Sensing

    Received: May. 22, 2024

    Accepted: --

    Published Online: Nov. 18, 2024

    The Author Email: CUI Haihua (cuihh@nuaa.edu.cn)

    DOI:10.37188/OPE.20243217.2686

    Topics