NUCLEAR TECHNIQUES, Volume. 48, Issue 2, 020204(2025)

Gamma scanning technique based on equivalent plane source method in large container

Li XU... Weiguo GU*, Hui YANG and Dezhong WANG |Show fewer author(s)
Author Affiliations
  • Machinery and Power Engineering College, Shanghai Jiao Tong University, Shanghai 200240, China
  • show less
    Figures & Tables(11)
    Schematic diagram of measurement system
    Layout of grid and detector position in x-y plane
    Layout of grid and detector position in y-z plane
    Variation of plane source detection efficiency with waste container position
    Variation of detection efficiency ratio with waste container position
    Simulation reconstruction results of 1.173 MeV plane source
    Simulation reconstruction results of 1.332 MeV plane source
    Schematic of volume source simulation
    • Table 1. Detector parameters

      View table
      View in Article

      Table 1. Detector parameters

      参数名称 Parameter参数值
      探测器类型 Detector typeHPGe
      晶体直径 Crystal diameter / mm6.09
      晶体长度 Crystal length / mm5.18
      冷指直径 Cold finger diameter / mm0.87
      冷指长度 Cold finger length / mm3.82
      死层厚度Dead layer thickness / mm0.07
      真空层厚度 Vacuum layer thickness / mm0.50
      铝壳厚度 Aluminum shell thickness / mm0.15
    • Table 2. Equivalent plane source method calculation results

      View table
      View in Article

      Table 2. Equivalent plane source method calculation results

      介质密度

      Density / g·cm-3

      真实位置

      Real position

      / cm

      等效面源计算结果

      Equivalent plane source

      误差

      Error / cm

      1.00.03.13.1
      10.010.70.7
      20.020.50.5
      30.031.71.7
      40.039.2-0.8
      50.047.4-2.6
      60.055.2-4.8
      70.069.7-0.3
      80.076.0-4.0
      90.083.0-7.0
      2.60.0-0.6-0.6
      10.07.2-2.8
      20.016.7-3.3
      30.029.1-0.9
      40.041.51.5
      50.048.0-2.0
      60.057.7-2.3
      70.069.3-0.7
      80.078.8-1.2
      90.086.3-3.7
    • Table 3. Volume source simulation results

      View table
      View in Article

      Table 3. Volume source simulation results

      工况

      Operating conditions

      X1 / cmX2 / cm

      Imeasured/Itrue

      ITGS

      Imeasured/Itrue

      TGS

      -90~90 cm86.188.621.6120.001
      -0~90 cm86.010.611.6940.045
      -90~0 cm1.1588.631.2620.359
      -70~70 cm68.769.101.2380.003
      0~70 cm68.61.431.0730.004
      -70~0 cm4.0269.041.2870.044
      -50~50 cm50.449.750.7550.564
      0~50 cm50.53.030.6881.949
      -50~0 cm0.5449.710.7631.334
    Tools

    Get Citation

    Copy Citation Text

    Li XU, Weiguo GU, Hui YANG, Dezhong WANG. Gamma scanning technique based on equivalent plane source method in large container[J]. NUCLEAR TECHNIQUES, 2025, 48(2): 020204

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: ACCELERATOR, RAY TECHNOLOGY AND APPLICATIONS

    Received: Oct. 11, 2023

    Accepted: --

    Published Online: Mar. 14, 2025

    The Author Email: GU Weiguo (GUWeiguo)

    DOI:10.11889/j.0253-3219.2025.hjs.48.230060

    Topics